Instruction manual
149
Graph (Monitor Area)
4
FUNCTION
• When sampling with Inside trigger, starting at the Rise of terminal RUN, with 10% of sampling data
before the trigger meets the condition
(1) Select "00" at St. No. field.
Select "Output Frequency" at Name field in CH1,
"RUN" in CH5, and "FU" in CH6.
(2) Make trigger setting as follows:
Select "Inside" at Type field.
Select "CH5" at CH field.
Select "Rise" at Start At field.
Set "10" at Position [%] field.
Set sampling interval and sampling time.
(3) Click to show "Sampling Pre-trigger
Data", and retrieves the data before the trigger
meets condition (10% of whole sampling time).
After the retrieval of the data before the trigger
meets condition, then the screen shows "Waiting
for Trigger" and becomes the trigger waiting state.
(4) When trigger meets the condition (Rise of terminal
RUN), sampling starts automatically.
(5) Click , or the sampling time has passed,
and the sampling is finished.
(6) Graph is adjustable for a better viewing.
(7) Graph data can be exported (Refer to page 94) for saving data as a file.
REMARKS
• In this example, "Position [%]" is set to "10%". The Rise of terminal RUN during the 10% of the whole sampling time after
clicking (during Pre-Trigger state) is ignored, and sampling is not started.
Set "00"
Select
"RUN"
Select
"FU"
Select "Output
Frequency"
Set "10"
Select "Inside"
Select "CH5"
Select "Rise"
Set Sampling Time
Set Sampling Interval
Click
Move the 0 position
of the selected graph
upper or lower
Set a value of each
one vertical grid
Set a value of each