Instruction manual
148
Graph (Monitor Area)
4.9.9 Example of graph sampling (monitoring output frequency, terminal RUN, terminal
FU)
• When sampling without trigger
(1) Select "00" at St. No. field.
Select "Output Frequency" at Name field in CH1,
"RUN" in CH5, and "FU" in CH6.
(2) Select "Not used" at Type field for trigger setting.
Set sampling interval and sampling time.
(3) Click to start sampling.
(4) Click , or the sampling time has passed,
and the sampling is finished.
(5) Graph is adjustable for a better viewing.
(6) Graph data can be exported (Refer to page 94) for saving data as a file.
Set "00"
Select
"RUN"
Select
"FU"
Select "Output
Frequency"
Set "Sampling Time"
Select "Not used"
Set "Sampling Interval"
Click
Click
Move the 0 position
of the selected graph
upper or lower
Set a value of each
one vertical grid
Set a value of each
one horizontal grid