Graph (Monitor Area)
4
FUNCTION
4.9.2 Explanation of window
No. Name Function and description
A
Start
Starts sampling. For High Speed sampling, the selected station is switched to the sampled
station.
B
Stop Stops sampling.
C
Clear
Clears the graph. If a graph has been displayed, data history is also cleared. If a graph has
not been displayed yet, the setting of sampling item is cleared.
D
Trigger/Sampling
Click to display trigger/sampling setting section. (Refer to page 141)
E
CH
Click to display sampling item setting section. (Refer to page 138)
F
Sampling item setting section
(Trigger/sampling setting section)
Click tabs to switch displaying Sampling item setting section (Refer to page 138) and Trigger/
sampling setting section (Refer to page 141).
G
Graph area Shows sampling data in graph form.
H
Scale changing section
(Cursor function section, History
display section)
Click tabs to switch displaying Scale changing section (Refer to page 145), Cursor function
section (Refer to page 146) and History display section (Refer to page 147).
I
Scale
Click to display Scale changing section. (Refer to page 145)
J
Cursor
Click to display Cursor function section. (Refer to page 146)
K
History
Click to display History display section. (Refer to page 147)
L
Graph (digital data)
Digital data drawn in graph form (CH5 to CH8). OFF is drawn on a grid line, and ON is
drawn between the grid lines.
M
Graph (analog data)
Analog data drawn in graph form (CH1 to CH4). Graph is drawn based on the setting of
Vertical Axis scale and 0 position adjust. Vertical Axis scale of each data (CH) can be
changed separately.
N
Trigger Line Shows a position of trigger start. "T" is displayed on top of Trigger Line.
Note
Each graph displays their own CH number. Though when a graph data is out from Graph area, CH number may not be
displayed. Adjust with 0 position adjust and scale changing to make a data visible inside of Graph area.
E
B C
F
G
D
A
H
JIK
L
M
N