Convert (System Area)
<When converting the FR-E500-N series to the FR-E700-NC series >
(1) The following parameters are not converted. Make a setting from "Parameter List" as required.
Pr. 160, Pr. 173 to Pr. 174 (User group selection)
(2) The following parameters are adjustment parameters. Parameter readjustment according to the machine is
recommended after converting.
Pr. 0 Torque boost
Pr. 12 DC injection brake voltage
Pr. 245 Rated slip
Pr. 246 Slip compensation time constant
(3) When General-purpose magnetic-flux vector control is selected ( Pr. 80 Motor capacity is not "9999") for FR-E500-N
series, note the following precautions.
When converting, motor pole is considered as 4 poles ( Pr. 81 Number of motor poles = "4"). Set the number of motor
poles of the using motor in Pr. 81.
Tuning and parameter setting of the target inverter are recommended, if offline auto tuning is performed ( Pr. 71 Applied
motor = "3, 13, 23, 103, 113, 123") or motor constants is directly input ( Pr. 71 = "5, 6, 15, 16, 105, 106, 115, 116") to the
source inverter.
When SF-HR or SF-HRCA type motor is used, set Pr. 71 = "40, 43, 44, 50, 53, 54" after writing the converted
parameter to the target inverter. (Conversion of Pr. 82, Pr. 86, Pr. 90 is not necessary)
(4) To operate FR-E700-NC via CC-Link communication, set Pr. 79 = "0 or 2" and check that the operation mode is NET
operation mode.
(5) There is a change in the following functions. Refer to the Instruction Manual of the FR-E700-NC series for details.
If STF signal is set as the start signal and STR signal is set as the forward/reverse signal (Pr. 250 = "1000 to 1100,
8888") in FR-E500-N, STF signal is converted as the forward rotation start signal and STR signal is converted as the
reverse rotation start signal (Pr. 250 = "0 to 100, 9999") for FR-E700-NC.
Set the communication station number and baud rate in Pr. 542 and Pr. 543 according to the rotary switch setting of FR-
E500-N.