Instruction manual
126
Convert (System Area)
(6) There is a change in the following functions. Refer to the FR-A700 series manual for details.
• When automatic restart after instantaneous power failure is performed with residual voltage detection system by T-
SEN50 ( Pr. 162 = "11"), it is changed to automatic restart after instantaneous power failure with reduced voltage
system. Fully check that there is no problem in automatic restart operation after instantaneous power failure. If there
are any problem, consider changing to f search system, etc.
• Y29 (acceleration speed detection) signal is deleted, and major fault by E.OS occurs instead.
• When stop position command of orientation control was given from the FR-A5AX ( Pr. 360 = "1"), orientation with the
number of encoder pulses (Pr. 369) 1025 to 2047, or 2049 to 4059 is not supported by Convert.
• Since convert is performed using the full scale value of the motor torque as 200%, the full scale value of the load meter
is converted as 200% (FR-A500 (L) series is 100%). Use Pr. 866 to change. In such a case, note that the full scale
value of the motor torque also changes accordingly.
(7) The following functions are not converted, since they have been deleted from the FR-A700 series.
• Pr. 53 PU level display data selection
• Pr. 199 User initial value
• Setting value 3, PRG signal (program operation) of Pr. 200 to Pr. 231 and Pr. 76, setting value 5 of Pr. 79
• Pr. 371 Torque characteristic selection
• Pr. 390 to Pr. 396 Trace function of the FR-A500L series
• Pr. 450 to Pr. 453 Motor constant adjustment function for vector control of the FR-A500L series and FR-A5AP (encoder
50)