Instruction manual

119
Convert (System Area)
4
FUNCTION
(2) When converting from a parameter file (PRM)
1) Click in "Convert" window to display
"Convert Method".
2) Select "Convert from a P
arameter File (PRM)". Click
after selecting.
3) Select the converting parameter file in "Select
Parameter File" screen. Click to display "Open"
window. Select a parameter file in that window.
4) Click to read the selected parameter file.
"Selection of Import Data" is displayed. Select between
Current Value or Setting Value for use. (Refer to page 94)
Check File Read result, and click .
5) Select the target inverter on the "Target Inverter"
window, and the convert setting is finished. Click
, and proceed to the next according to the
message on the window.
6) The value of some of the source parameter is available
for changing. When changing the parameter setting
value, enter a changed value in Setting field.
When the convert setting is finished, in
"Convert" window becomes available. Click
to display "Convert Confirmation".
7) Check the information of the source inverter and target
inverter. Click and proceed to the next
according to the messages appear in the screen to
convert parameters.
8) Click , when "Parameter converting is
finished" is displayed.
[Convert from a
parameter file (PRM)]
Click to read the
parameter file
Click to display
"Open" window
Select the target
inverter
Click to display "Convert Confirmation"
Click to convert
parameters