Instruction manual

116
Convert (System Area)
4.7.2 Explanation of window
No. Name Function and description
A
Source Information Displays "Convert Method" window. Set converting method, source and target model setting.
B
Parameter Convert
Displays "Convert Confirmation" window. Parameter converting is available.
(Click after converting method, source and target model information is set.)
C
Reflect to the Target
Displays "Parameter saving" window. Reflect the converted setting into a Parameter List of the
selected inverter. Saving to a parameter file (PR3) is also available.
(Click after the parameter is converted.)
D
Simultaneous Scroll of both
Parameter List
Checked : When scrolling one of source/target parameter list, the other parameter list also scrolls.
Without check : Even when scrolling one of source/target parameter list, the other parameter list
does not scroll.
E
Source inverter information Shows the inverter model of the source.
F
Parameter List of source
Shows parameter setting read from the source. " >" appears next to the parameter number of which
the setting has been changed, and also a color turns green.
G
Clear data
Initialize the all setting data. Confirmation dialog is displayed when clicked. Click to
initialize when a confirmation dialog is displayed.
H
Target inverter information Shows the inverter model of the target.
I
Parameter List of target
Shows converted parameter setting. " > " appears next to the parameter number of which the setting
has changed, and also a color turns green.
REMARKS
Double-click a parameter name, or select a parameter and press F1 key to display a description of the selected parameter in the
help window.
A
B
C
D
G
F
I
E
H