Instruction manual
114
Convert (System Area)
4.7 Convert (System Area)
Converting a parameter setting from a conventional model into 700 series inverter parameter setting is available. Select
[Convert] in [View] menu to display "Convert".
• Compatible models for Convert
Voltage class of the target inverter follows the voltage class of the source inverter.
Source Inverter Target Inverter REMARKS
FR-V500(L) FR-A700 Setting of plug-in options is changed. (Refer to page 123)
FR-A500(L) FR-A700
FR-E500(S)(W)
FR-D700(S)(W)
FR-E700(S)(W)(SC)(NC)
FR-E510W is recognized as FR-E520 when detecting the source inverter through
communication. Select FR-E710W for the target inverter.
FR-E500-N FR-E700(SC)(NC)
FR-F500(L)
FR-F700
FR-F700P
Setting of plug-in options is changed. (Refer to page 123)
FR-F500J
FR-D700
FR-F700PJ
FR-S500(S)(W)(E) FR-D700(S)(W)
Note
• Parameter name in an inverter manual and the one in FR Configurator can be different, but the function of each
parameter is the same.
• FR-A701 is not compatible for the convert.