Instruction manual

5
1
OUTLINE
System Configuration
1.2.3 System configuration
The following devices are required to use FR Configurator. Setup the system in accordance with the instruction manual of
each device.
 When using serial port of a personal computer, a commercially
available converter is required.
Examples of product available on the market (as of February 2012)
Model: DINV-CABV (with connectors and cable)
Diatrend Corp.
The converter cable cannot connect two or more inverters (the
computer and inverter are connected on a 1:1 basis). This is a RS-
232C/RS-485 conversion cable with built-in converter. No additional
cable or connector is required. Contact a manufacturer for details of the
product.
 Connection cable
Examples of product available on the market (as of February 2012)
Connector: RJ45 connector
Example: Tyco Electronics
5-554720-3
Cable: Cable in compliance with EIA568 (such as 10BASE-T cable)
Example: Mitsubishi Cable Industries, Ltd.
SGLPEV-T (Cat5e/300m) 24AWG x 4P
 USB/RS-485 convert cable
Examples of product available on the market (as of February 2012)
Model: DINV-U4
Diatrend Corp.
Refer to page 49 for the communication setting with DINV-U4.
When using USB/RS-485 convert cable, use the newest driver
software. For a product details or the newest driver software, contact
the cable manufacturer.
 Recommended USB cable for computer-inverter connection (For FR-
E700)
MR-J3USBCBL3M Cable Length 3m
 Communication with PU connector, RS-485 terminal, or USB
connector(FR-A700, A701, E700 series only) is available.
 Available communication port is USB or serial port (one of port 1 to 63),
and set in Communication settings screen of FR Configurator. (Using
multiple port at the same time is unavailable) Connection of a computer
to GOT is 1:1 connection.
When using USB for connecting with GOT, use dedicated cable GT09-
C30USB-5P or GT09-C20USB-5P.
 Overall length of connection cable: 500m
 GOT RS-422 communication unit (GT15-RS4-9S) is required. The
number of connectable inverter depends on GOT. Refer to GOT1000
series connection manual for details of RS-422 connection and
compatible version of GOT.
RS-485 cable
*2
Using USB connector
FR Configurator
Commercially available
printer
Multidrop link system
GOT RS-422
Communication
unit
USB
connector
Connection cable
RS-485/RS-422
*7
*8
Inverter Inverter
USB
connector
PU
connector
RS-485
terminal
RS-485
terminal
InverterInverter Inverter
RS-485
terminal
RS-485
terminal
RS-485
terminal
Serial port
USB connector
or serial port
*3
Converter
*1
Converter
*6
*4
*5
Inverte
Product Type Manufacturer
1)
10BASE-T
cable
SGLPEV-T (Cat5e/300m)
24AWG x 4P
Mitsubishi Cable
Industries, Ltd.
2)
RJ-45
connector
5-554720-3 Tyco Electronics
Connector for personal computer
A-connector
Connector for inverter
mini B-connector (5 pin)