Parameter List (System Area)
4.6 Parameter List (System Area)
"Parameter List" has the following functions.
• Showing parameters (all list, functional, individual, changed parameter, verification result parameter)
• Editing Individual List
• Reading and batch reading of parameter setting value
• Input, writing and batch writing of parameter setting value
• Parameter clear and all parameter clear
• Parameter verification (verifies parameter values set on FR Configurator and values already written into the inverter)
• Parameter searching
• File output of parameter verification results, batch read, and batch write.
• Writing of comment
• Parameter copy (use import/export. Refer to page 94. )
Select [Parameter List] under [View] menu, or click on the tool bar to display "Parameter List".
The functions available in "Parameter List" are different between ONLINE or OFFLINE.
Function ONLINE OFFLINE
All Parameter Clear –
Parameter Clear –
Batch Read –
Batch Write –
Verification –
Read –
Write –
Input of parameter setting value
Edit Individual List
Search
Display list selection
Writing of comment
: Available, – : Not available
Note
• The Parameter List of FR Configurator supports the newest inverter. Setting range, initial value, number of parameters
may differ to the inverter produced before upgrade (function addition).
• Parameter name in an inverter manual and the one in FR Configurator may be different, but the function of each
parameter is the same.
• Pr. 296 and 297 are not shown in Parameter List. Pr. 296 and 297 do not change when importing parameter setting from
other inverters. Change the Pr. 296 and 297 settings from the operation panel or parameter unit.