Instruction manual

106
Parameter List (System Area)
4.6 Parameter List (System Area)
"Parameter List" has the following functions.
Showing parameters (all list, functional, individual, changed parameter, verification result parameter)
Editing Individual List
Reading and batch reading of parameter setting value
Input, writing and batch writing of parameter setting value
Parameter clear and all parameter clear
Parameter verification (verifies parameter values set on FR Configurator and values already written into the inverter)
Parameter searching
File output of parameter verification results, batch read, and batch write.
Writing of comment
Parameter copy (use import/export. Refer to page 94. )
Select [Parameter List] under [View] menu, or click on the tool bar to display "Parameter List".
The functions available in "Parameter List" are different between ONLINE or OFFLINE.
Function ONLINE OFFLINE
All Parameter Clear
Parameter Clear
Batch Read
Batch Write
Verification
Read
Write
Input of parameter setting value
Edit Individual List
Search
Display list selection
Writing of comment
: Available, : Not available
Note
The Parameter List of FR Configurator supports the newest inverter. Setting range, initial value, number of parameters
may differ to the inverter produced before upgrade (function addition).
Parameter name in an inverter manual and the one in FR Configurator may be different, but the function of each
parameter is the same.
Pr. 296 and 297 are not shown in Parameter List. Pr. 296 and 297 do not change when importing parameter setting from
other inverters. Change the Pr. 296 and 297 settings from the operation panel or parameter unit.