Instruction manual
99
Test Operation (Navigation Area)
4
FUNCTION
4.4.4 Setting of running frequency (speed, machine speed)
Input a set frequency (speed, machine speed) in "Frequency (Speed) input" field, and click to write the set frequency
into the inverter. Use the buttons on the right of the input field to add or decrease the setting frequency by minimum setting
increments. (Available only when ONLINE.)
When the set frequency is written, "F" and the set frequency is displayed alternately 3 times. After displaying 3 times, the
display shows output frequency (speed, machine speed).
Add or decrease the frequency
(motor speed, machine speed) by
minimum setting increments.
Input setting frequency (motor
speed, machine speed)
Click after inputting the
frequency (motor speed,
machine speed)
Displays 3 times alternately