Instruction manual

97
Test Operation (Navigation Area)
4
FUNCTION
4.4 Test Operation (Navigation Area)
Frequency (fault) indication, operation mode indication and switching, sending of forward/reverse rotation command and
writing of the set frequency are available.
4.4.1 Test operation screen
Note
For safety issue, command sending part of Test Operation is hidden at start up of FR Configurator.
When performing Test Operation, check [T
est Operation] sub-menu under [Navigation] of [View] menu to display the
command sending part of Test Operation.
No. Name Function and description
A
Frequency (Speed)
indication
Shows frequency (speed) or fault indication etc. of the selected inverter.
B
Set frequency (speed) input
field
Input the set frequency and click to write the set frequency to the selected inverter. Pressing
while the field is empty shows the output frequency of the selected station.
C
SET Writes the value of "Frequency (speed) input" field as the set frequency of the selected inverter.
D
STOP Sends stop command to the selected inverter.
E
PU Changes the operation mode of the selected inverter to PU operation mode.
F
EXT Changes the operation mode of the selected inverter to External operation mode.
G
NET Changes the operation mode of the selected inverter to Network operation mode.
H
Operation mode indication Shows the operation mode of the selected inverter in red.
I
Rotation direction indication At forward rotation, "FWD" turns red, and at reverse rotation "REV" turns red.
J
FWD
Sends forward rotation command to the selected inverter. Performing test operation during the button
is pressed. (When "Release Test Operation" is selected, clicking button once keeps operation. Refer to
page 91)
K
REV
Sends reverse rotation command to the selected inverter. Performing test operation during the button
is pressed. (When "Release Test Operation" is selected, clicking button once keeps operation. Refer to
page 91)
Only this part is displayed.
Command sending part of Test Operation is hidden.
A
H
EFG
I
DC
K
J
B