Service manual

5
PART NAMES AND FUNCTIONS
2
Drainage hose
Piping
Air inlet
Air inlet
Air outlet
Drain outlet
(back and side)
Air outlet
(back and side)
OUTDOOR UNIT
MU-A18WV -
MU-A24WV -
E1
E1
MU-A30WV -
E1
SPECIFICATION
3
Outdoor model
Function
Power supply
Capacity
Dehumidification
Air flow(High)
Power outlet
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at 20:)
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Sound level(High)
Fan speed(High)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigerating oil (Model)
kW
r/h
K /h
A
A
W
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
MU-A18WV -
E1
Cooling
Single phase
230V, 50Hz
5.0
2.5
2,196
15
7.90
1,750
96
37
7.51
0.39
2.76
RN196VHSHT
1,300
C-R 1.80
C-S 3.00
RA6V50-OG
WHT-BLK 116
BLK-RED 111
850o605o290
44
52
828
1
1.40
520 (NEO22)
MU-A24WV -
E1
Cooling
Single phase
230V, 50Hz
6.5
3.4
2,322
25
10.82
2,420
97
74
10.27
0.55
2.62
NN29VBAHT
1,900
C-R 0.80
C-S 1.64
RA6V60-MA
WHT-BLK 71
BLK-RED 89
850o605o290
60
53
873
1
1.90
1,200 (NEO22)
Electrical
data
Compressor
Fan
motor
Special
remarks
Coefficient of performance(C.O.P)
Capacity
NOTE: Test conditions are based on JIS C 9612.
Cooling : Indoor DB27°C WB19°C
Outdoor DB35°C WB(24°C)
Indoor-Outdoor piping length : 5m
OB326A-1.qxp 04.2.9 10:41 AM Page 5