Operating instructions
En-5
• OPERATING INSTRUCTIONS •
I FEEL mode
The unit selects the operation mode according to the room temperature
when AUTO is selected. When the room temperature is higher than 77°F
(25°C),
COOL is selected (set temperature: 75°F [24°C]). When the room
temperature is
lower than 77°F (25°C), DRY is selected. However, when
operation is stopped
and then started within 2 hours, the mode which has
been selected previously is operated.
Note:
During COOL operation, the set temperature may not be changed when
the room temperature is more than 4°F (2°C) higher than the set tempera-
ture. In this
case, please wait until the room temperature drops to within
4°F (2°C) of the set temperature.
COOL mode
Enjoy cool air at your desired temperature.
Do not operate COOL mode at low outside temperature
(less than 14°F [-10°C]).
Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
FAN mode
Circulate the air in your room.
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication Operation state Room temperature
The unit is operating to reach the set
temperature
About 4°F (2°C)
or
mor
e away from set
temperature
The room temperature is approach-
ing the set temperature
About 2 to
4°F (1 to
2°C) from set tem-
perature
Lighted Not lighted
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation
switch (E.O.SW) on the indoor unit.
Eac
h time the E.O.SW is pressed, the operation
changes in the following order:
1
Press
to start the operation.
2
Press to select operation mode. Each press
changes mode in the following order:
3
Press or to set the temperature.
Each press raises or lowers the temperature by 1°F
(1°C).
Press to stop the operation.
• The same setting is selected the next time by simply pressing
.
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto
restart function” automatically starts operation in the same mode as the one
set with
the remote controller just
before the shutoff of the main power.
When timer is set, timer setting is cancelled and the unit starts operation when
power is resumed.
If
you do
not want to use this function, please consult the serv-
ice representative because the setting of the unit needs to be
changed.
SELECTING OPERATION MODES
(I FEEL)
(COOL)
(DRY)
(FAN)
Oper
ation indicator lamp
Emergency COOL
Stop
Note:
The fi rst 30 minutes of operation is test run. Temperature
control does not work, and fan speed is set to High.
WASH
reset
E.O.
SW
Set temperature : 75°F
(24°C)
Fan speed : Medium
Horizontal vane : Auto
SG79Y951H01_EN.indd 5 4/9/07 4:19:55 PM