Installation guide

ae
1-2.
SELECTING
THE
INSTALLATION
LOCATION
INDOOR
UNIT
*
Where
airflow
is
not
blocked.
+
Where
cool
air
spreads
over
the
entire
room.
*
Rigid
wall
without
vibration.
+
Where
it
is
not
exposed
to
direct
sunshine.
+
Where
easily
drained.
*
Ata
distance
3
ft.
(1
m)
or
more
away
from your
TV
and
radio.
Operation
of
the
air
conditioner
may
inter-
fere
with
radio
or
TV
reception.
An
amplifier
may
be
required
for
the
affected
device.
*
Ina
place
as
far
away
as
possible
from
fluorescent
and
incandescent
lights
(so
the
infrared
remote
control
can
operate
the
air
conditioner
normally).
*
Where
the
air
filter
can
be
removed
and
replaced
easily.
Note:
Install
indoor
unit
at
a
high
position
on
the
wall
where
air
can
distribute
over
the
entire
room.
*
Where
itis
easy
to
operate
and
easily
visible.
*
Where
children
cannot
touch
it.
*
Select
a
position
about
4
ft.
(1.2
m)
above
the
floor
and
check
that
signals
from
the
remote
controller
are
surely
received
by
the
indoor
unit
from
that
position
(beep’
or
‘beep beep’
receiving
tone
sounds).
After
that,
attach
remote
controller
holder
to
a
pillar
or
wall
and
install
wireless
remote
controller.
1-3.
SPECIFICATIONS
1-3-1.
POWER
SUPPLY
AND
INDOOR/OUTDOOR
WIRE
CONNECTION
*
Power
should
be
taken
from
an
exclusive
branched
circuit.
*
Wiring
work
should
be
based
on
applicable
technical
standards.
*
Wiring
connections
should
be
made
following
the
diagram.
*
Screws
should
be
tightened
so
they
will
not
loosen.
Connecting
wires
and
connecting
ground
wire
«
Use
solid
conductor
AWG14
or
stranded
conductor
AWG14.
*
Use
double
insulated
copper
wire
with
GOOV
insulation.
*
Use
copper
conductors
only.
*
Follow
local
electrical
code.
Power
supply
cable
and
ground
wire
*
Use
solid
or
stranded
conductor
AWG14.
*
Use
copper
conductors
only.
*
Follow
local
electrical
code.
Note:
In
rooms
where
inverter
type
fluorescent
lamps
are
used,
the
signal
from
the
wireless
remote
controller
may
not
be
received.
+
Where
itis
not
exposed
to
strong
wind.
+
Where
airflow
is
good
and
dustless.
*
Where
neighbours
are
not
annoyed
by
operation
sound
or
hot
air.
*
Where
rigid
wall
or
support
is
available
to
prevent
the
increase
of
operation
sound
or
vibration.
*
Where
there
is
no
risk
of
combustible
gas
leakage.
+
When
installing
the
unit
at
a
high
level,
be
sure
to
se-
cure
the
unit
legs.
+
Where
it
is
at
least
10
ft.
(3
m)
away
from
the
antenna
of
TV
set
or
radio.
Operation
of
the
air
conditioner
may
interfere
with
radio
or
TV
reception
in
areas
where
re-
ception
is
weak.
An
amplifier
may
be
required
for
the
affected
device.
*
Install
the
unit
horizontally.
*
Please
install
it
in
an
area
not
affected
by
snowfall
or
blowing
snow.
In
areas
with
heavy
snow,
please
install
a
canopy,
a
pedestal
and/or
some
baffle
boards.
Electrical
specifications
Note:
*
tis
advisable
to
make
a
piping
loop
near
outdoor
unit
so as
to
reduce
vibration
transmitted
from
there.
*
For
increased
efficiency,
install
the
outdoor
unit
in
a
location
where
continuous
direct
sunlight
or
excessive
water
can
be
avoided
as
much
as
possible.
Note:
When
operating
the
air
conditioner
in
low
outside
temperature,
be
sure
to
follow
the
instructions
described
below.
*
Never
install
the
outdoor
unit
in
a
place
where
its
air
inlet/outlet
side
may
be
exposed
directly
to
wind.
*
To
prevent
exposure
to
wind,
install
the
outdoor
unit
with
its
air
inlet
side
facing
the
wall.
*
To
prevent
exposure
to
wind,
it
is
recommended
to
in-
stall
a
baffle
board
on
the
air
outlet
side
of
the
outdoor
unit.
Avoid
the
following
places
for
installation
where
air
conditioner
trouble
is
liable
to
occur.
*
Where
flammable
gas could
leak.
*
Where
there
is
much
machine
oil.
*
Salty
places
such
as
the
seaside.
«
Where
sulfide
gas
is
generated
such
as
a
hot
spring.
«
Where
there
is
high-frequency
or
wireless
equipment.
Note:
When
the
indoor
unit
is
powered
from
the
outdoor
unit,
a
disconnect
switch
needs
to
be
installed
to
power
supply
circuit
(between
indoor and
outdoor
unit)
depending
on
local
code.
1-3-2.
REFRIGERANT
PIPES
*
Ensure
that
the
2
refrigerant
pipes
are
insulated
to
prevent
condensation.
*
Refrigerant
pipe
bending
radius
must
be
4
in.
(100
mm)
or
more.
A\
CAUTION
Be
sure
to
use
the
insulation
of
specified
thickness.
Excessive
thickness
may
cause
incorrect
installation
of
the
indoor
unit
and
lack
of
thickness
may
cause
dew
drippage.
*
This
unit
has
flared
connections
on
both
indoor
and
outdoor
sides.
*
Remove
the
outdoor
units
valve
cover,
then
connect
the
pipe.
*
Refrigerant
pipes
are
used
to
connect
the
indoor
and
outdoor
units.
*
Be
careful
not
to
crush
or
bend
the
pipe
in
pipe
bending.
*
Refrigerant
adjustment...
lf
pipe
length
exceeds
25
ft.
(7
(R410A)
charge
is
required.
(The
outdoor
unit
is
charged
with
refrigerant
for
pipe
length
up
to
25
ft.
[7
m])
MSz-
MSzZ-
A15M7NA
MS-
MS-
MODEL
Aogi2NA|
mMSY-
|
Aogwa
|
A12WA
A15M7NA
INDOOR
UNIT
Power
supply
(V,
PHASE,
Hz)
208/230,
1,
60
115,
1,
60
Min.
Circuit
Ampacity
10
|
1.0
12
|
1.2
Fan
motor
(F.L.A.)
0.76
0.95
OUTDOOR
UNIT
Power
supply
(V,
PHASE,
Hz)
208/230,
1,
60
115,
1,
60
Max.
Fuse
size
(time
delay)
(A)
15
15
15
20
Min.
Circuit
Ampacity
12 14 14 16
Fan
motor
(F.L.A.)
0.52 0.52 0.63
0.926
(R.L.A)
7.8
10.1
9.30
10.82
Compressor
(L.R.A)
9.2
12
47
56
Indoor
unit
-
Remote
Indoor
unit
-
Remote
controller:
(Wireless)
controller:
(Wireless)
Control voltage
Indoor
unit
-
Outdoor
Indoor
unit
-
Outdoor
unit:
DC12-24V
(Polar)
unit:
AC115V
Outside
van
Insulation
.
Pipe
diameter
thickness
|
[nsulation
mate-
ness
rial
inch
(mm)
we
0.0315
For
liquid 1/4
(6.35)
(0.8)
5/16
(8)
MSZ-
AOS2NA
|
3/8
(9.52)
08)
5/16
(8)
|
Heat
resisting
MS-AO9WA
foam
plastic
0.045
Specific
For
gas
|
MSZ-
ravit
.
A15/17NA
0.0315
gravity
MSY-A15/
|
1/2
(12.7)
(0.8)
5/16
(8)
17NA
,
MS-A12WA
a
MSZ-A09/1
2/1
5/17NA
Limits
MSY-A15/417NA
MS-A09/12WA
Pipe
length
65ft.
(20
m)
max.
65ft.
(20
m)
max.
Height
difference
40
ft.
(12
m)
max.
35
ft.
(10
m)
max.
m),
additional
refrigerant
No.
of
bends
10
max.
10
max.
Up
to
25
ft.
(7m)
No
additional
charge
is
required.
Pipe
length
:
Additional
charge
is
required.
Exceeding
26
ft.
(7m)
(Refer
to
the
table
below.)
MSZ-A09/12/15/17NA
1.62
oz
each
5
ft.
(30g/m)
Refrigerant
to
be
MSY-A1S/17NA
added
MS-A09/12WA
1.08
oz.
each
5
ft.
(20g/m)