Specifications

78
Model name
AJ65VBTCU-68DAVN
Digital value
Analog output
Input/output characteristics
Accuracy
(Accuracy relative to the maximum
analog output value)
Output range switching
Offset/gain setting
Maximum conversion speed
Output short-circuit protection
Absolute maximum output
Number of analog output points
Station type
Number of occupied stations,
Expanded cyclic setting
CC-Link-compatible function
Isolation method
External connection method
Applicable
wire size
Applicable DIN rail
External power supply
Inrush current
Internal current consumption
Weight
External dimensions
16-bit signed binary (-4096 to +4095)
10 to + 10 VDC (external load resistance: 2 k to 1 M)
For each channel
Yes
1 ms/channel
Yes
12V
8 channels/module
Remote device station
Ver. 1 mode: 3 stations (RWr/RWw 12 words each, RS/RY 32 points)
Ver. 2 mode: 1 station (extended word (RWr/RWw) 16 words each, RX/RY 32 points), Quadruple
Cyclic transmission, extended cyclic transmission, station-to-station cable length relaxation
0.66 to 0.98 mm
2 (AWG18) [ 2.2 to 3.0 mm], wire size 0.08 mm2 or more
24 VDC(20.4 to 26.4 VDC with a ripple rate of 5% or less)
4.3 A, 1.2 ms max.
0.15A
0.16kg
41W115H63D
Voltage
10 to 10 V
User range setting 1
(10 to 10 V)
0 to 5 V
1 to 5 V
User range setting 2
(0 to 5 V)
4000 to 4000
0.3
30mV
0.2
20mV
0.3
15mV
0.2
10mV
2.5mV
1.25mV
1.0mV
1.25mV
0 to 4000
Analog
Ambient temperature
0 to 55 
Ambient temperature
25 5 
Digital
Maximum
resolution
Accuracy
One-touch connector
for communication
One-touch connector
for power supply
One-touch connector
for analog I/O
One-touch connector for communication [transmission circuit] (5-pin/solderless type. The connector plug is sold separately.)
One-touch connector for power supply and FG [module power supply and FG] (5-pin/solderless type. The connector plug is sold separately.)
One-touch connector for analog input (4-pin/solderless type. The connector plug is sold separately.)
(Optional parts) Online connector for communication: A6CON-LJ5P, online connector for power supply: A6CON-PWJ5P
Communication line: CC-Link dedicated cable compatible with Ver.1.10, 0.5 mm
2
(AWG20) [ 2.2 to 3.3 mm]
Shielded power supply 0.5 mm
2
(AWG20)
1.0 to 1.4 mm (A6CON-P214), 1.4 to 2.0 mm (A6CON-P220), [applicable wire size: 0.14 to 0.2 mm
2
]
1.0 to 1.4 mm (A6CON-P514), 1.4 to 2.0 mm (A6CON-P520), [applicable wire size: 0.3 to 0.3 mm
2
]
TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812)
Metal fitting for CC-Link connector type: A6PLT-J65V1
Between communication system and batch of analog outputs: Photocoupler isolation
Between power supply system and batch of analog outputs: Photocoupler isolation
Between channels: No isolation
Digital to analog converter module
AJ65VBTCU-68DAVN
Analog I/O Module
Compatible with Ver. 2
The module having occupied three stations for eight channels is renewed to be compatible with CC-Link
Ver. 2 and occupies one station for eight channels. With this change, up to 42 modules can be connec-
ted to a single master. Using a rotary switch, the module can be used as a conventional ver. 1 module.
High precision
These modules perform D/A conversion at an accuracy of 0.3% of the maximum analog output value
when the operating ambient temperature is 0 to 55˚C, and at an accuracy of 0.2% of the maximum
analog output value when the operating ambient temperature is 25 5˚C.
It is possible to switch between different output ranges for each channel.
It is possible to switch between different analog input ranges for each channel, and to change the in-
put/output conversion characteristics.
A high resolution of 1/ 4000 is possible.
A high resolution of the analog output can be obtained. By switching to the proper output range, it is
possible to achieve resolution of the analog output of either 1/4000 or 1/ 4000. (If the output should
be in the -10 to +10 V range, user range setting 1 should be selected.)
It is possible to set to retain or clear analog output when the PLC CPU stops.
It is possible to specify whether to retain or clear the analog values output from each channel of the
module immediately before the PLC CPU stops or the D/A conversion is stopped due to an error.
More channels compared to conventional D/A conversion module
The number of channels is four times more compared to the conventional CC-Link D/A conversion mod-
ule (AJ65SBT-62DA).
It is possible to dramatically reduce the man-hours needed for wiring work.
One-touch connectors of loose wire pressure-welding connection method (eliminating the need for solder-
ing, wire stripping and screw tightening) are used for the communication cable and power-supply cable con-
nections. Therefore it is possible to dramatically reduce the man-hours needed for wiring work.
Dramatically improved ease of wiring
One-touch connectors allow separate connections for the IN and OUT sides. This dramatically im-
proves the ease of wiring, particularly when connecting wires within the board. (The I/O module wiring
and power-supply wiring cannot be mixed up and interconnected by mistake.)
It is possible to replace a module without stopping the CC-Link system.
By using the online connector (for communication and power supply), it is possible to replace a module
without stopping the CC-Link system.
Performance Specifications See page 154 for the general specifications.
Product
Description
Product
Description
Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection
New