Specifications



 


X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC
COM COM
MITSUBISHI A J65SBTCF1-32D
66
AJ65SBTCF1-32
Operation LED display
PW
L RUN
L ERR
LED name Item checked
AJ65SBTCF1-32D
AJ65BTC1-32D
DC input (sink/source common type)
DC input (sink, source type)




32 points
32 points
24 VDC
24 VDC
14 V min.
14 V min.
6 V max.
6 V max.
1.5 ms max.
10 ms max.
32 points
1 common
32 points
1 common
45mA
70mA
60mA
115mA
One wire type
One wire type
One wire type
One wire type
12/24 VDC
12/24 VDC




1.5 ms
max.
2 ms
max.
0.5 ms
max.
0.5 ms
max.




32 points
32 points
Transistor output (sink type)
Transistor output (sink type)
AJ65SBTCF1-32T
AJ65BTC1-32T
ON voltage OFF voltage
1 point
0.1A
0.1A
1 common
3.2A
2A
OFFON ONOFF
Output module
model name
Output type Number
of output
points
Isolation
method
Rated
load
voltage
Surge
suppression
Maximum load current External
connection
wire type
Internal
current
consumption
Common
connection
Output response time
Input module
model name
Input type Number of
input points
Isolation
method
Rated input
voltage
External
connection
wire type
Internal
current
consumption
Common
connection
Operating voltage Input
response time
AJ65SBTCF1-32DT
AJ65VBTCF1-32DT1
One wire type
One wire type
Photocoupler
/photocoupler
16 points 1 common
/16 points 1 common
50mA
50mA
24 VDC
24 VDC
0.1A
0.1A
0.8A
1.6A
16 points
/16 points
Sink, source type
/ sink type
DC input
/ transistor output
Photocoupler
/photocoupler
12/24
VDC
12/24
VDC
16 points 1 common
/16 points 1 common
16 points
/16 points
Zener
diode
Zener
diode
0.5 ms
max.
0.5 ms
max.
6 V
max.
3 V
max.
14 V
min.
15 V
min.
1.5 ms
max.
1.5 ms
max.
Sink, source type
/ sink type
DC input
/ transistor output
1.5ms
0.2ms
ON
voltage
1
point
Input Load
1
common
OFFON ONOFF
OFF
voltage
I/O module
model name
I/O type Number
of I/O
points
Isolation
method
Input
response
time
Rated voltage Surge
suppression
Maximum load
current
External
connection wire
type on input
/output sides
Internal
current
consumption
Common
connection
Operating voltage
Output response time
Turns on when the power supply to the
remote I/O module is turned on.
Turns on when normal data is received from
the master station, and turns off via timeout.
"10," "20," and "40" in STATION NO.
are used for setting the second digit
of the station number.
"1," "2," "4," and "8" in STATION NO.
are used for setting the first digit of
the station number.
Displays the on/off status of input. The
LEDs turn on in the "On" state, and off in
the "Off" state.
Turns on in case of a transmission error
(CRC error) and turns off via timeout (L
RUN also turns off). It turns on if the set-
tings for station number and transmission
speed are wrong. It flashes if the station-
number and transmission-speed settings
are changed while the communication is
active.
Transmission speed
setting switch
Station number
setting switches




156 kbps
625 kbps
2.5 Mbps
5.0 Mbps
10 Mbps
 Transmission speed
X0 to 1F
Y0 to 1F
Input/output display
selector switch
DIN rail hook
Hook for mounting the module to
the DIN rail
Connector for input/output signals
The compact remote I/O module power supply, transmission,
and I/O signals are connected here.
Terminal block
Connector

FCN Connector Type
AJ65SBTCF- AJ65VBTCF- AJ65BTC-
Remote I/O
Saves labor due to easy wiring
Due to the use of 40-pin connectors for I/O, the man-hours needed for wiring work are dramatically reduced.
Performance Specifications See page 154 for the general specifications.
Name and Setting of Each Part
Product
Description
Product
Description
Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection