Specifications

Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection
59
Remote I/O AJ65FBTA-16□ AJ65SBTW4-16
Name and Setting of Each Part
AJ65FBTA-16
AJ65SBTW4-16
LINK CABL IN POWER CABL
LINK CABL OUT POWER CABL
CON1
CON2
CON3
CON4
CON5
CON6
CON7
CON8
X0
PW
Y8
X1 Y9
L RUN
L ERR.
X2 YA
X3 YB
X4 YC
X5 YD
X6 YE
X7 YF
STATION NO.
AJ65SBTW4-16DT
ON
40 10 4 1 2208241
STATION NO B RATE
Communication adapter (front side)
Communication adapter connector
Communication adapter
(back side)
Main body connector
ON
TERMINATION
110 130
AJ65FBTA42-16DTE
PROTECT
Y8
Y9
YA
YB
YC
YD
YE
YF
Y
Y
Y
Y
Y
Y
Y
Y
Communication
adapter
Operating condition LED display
Waterproof connector
for power-supply line
Transmission speed setting switch
Waterproof connector
for transmission line
Waterproof connector
for input/output
Operation LED display
FG metal fittings
Waterproof connector
for input/output line
Sink/source selector switch
(only for AJ65SBTW4-16D)
FG metal fittings
Module top-cover mounting screw
Module front-cover mounting screw
0
1
2
3
4
156 kbps
625 kbps
2.5 Mbps
5.0 Mbps
10 Mbps
Setting value Transmission speed
Terminal resistor setting
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Dip switch 1 Dip switch 2
No terminal resistor
110terminal On
130terminal On
Setting prohibited
Description
Description
POWER
L RUN
L ERR.
PROTECT
On: Power supply is turned on.
On: Communication is normal.
Off: Communication is normal.
Off: Normal
On: Protection function is enabled.
Item checkedLED name
PW
L RUN
L ERR
X0 to 1F
Y0 to 1F
Station number setting switches
"10," "20," and "40" in STATION NO. are used for set-
ting the second digit of the station number.
"1," "2," "4," and "8" in STATION NO. are used for set-
ting the first digit of the station number.
Switch the +COM, COM type to either sink
or source type.
SINK SOURCE
Terminal block
Through pipe for transmission/module power supply line
Turns on when the power supply to the
remote I/O module is turned on.
Turns on when normal data is received
from the master station, and turns off
via timeout.
Turns on in case of a transmission
error (CRC error) and turns off via
timeout (L RUN also turns off). It turns
on if the settings for station number
and transmission speed are wrong. It
turns on if the station-number and
transmission-speed settings are
changed while the communication is
active.
Displays the on/off status of input. The
LEDs turn on in the "On" state, and off
in the "Off" state.
Station number setting switches
"10," "20," and "40" in STATION NO. are used for set-
ting the second digit of the station number.
"1," "2," "4," and "8" in STATION NO. are used for set-
ting the first digit of the station number.
Transmission speed setting switch
0
1
2
3
4
156 kbps
625 kbps
2.5 Mbps
5.0 Mbps
10 Mbps
Setting value Transmission speed
Product
Description