Specifications

27
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61BT11
A1SJ61BT11
12345678
O N K S D 0 8
STATION NO. MODE
X
10
X
1
B RATE
0 156K
1 625K
2 2. 5M
35M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUN
ERR.
MST
S MST
LOCAL
CPU R / W
L RUN
L ERR.
SD
RD
SW
M / S
PRM
TIME
LINE
E
R
R
O
R
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
ISM SFM
1/4 2/3
A1SJ61BT11
RUN
ERR.
MST
S MST
LOCAL
CPU R / W
L RUN
L ERR.
SD
RD
SW
M / S
PRM
TIME
LINE
E
R
R
O
R
STATION NO.
X
10
X
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
MODE
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
12345678
O N K S D 0 8
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
ISM SFM
1/4 2/3
B RATE
0 156K
1 625K
2 2.5M
35M
4 10M
0
5
9
4
8
3
7
2
6
1



10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61BT11
A1SJ61BT11
12345678
O N K S D 0 8
STATION NO. MODE
X
10
X
1
B RATE
0 156K
1 625K
2 2. 5M
35M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUN
ERR.
MST
S MST
LOCAL
CPU R / W
L RUN
L ERR.
SD
RD
SW
M / S
PRM
TIME
LINE
E
R
R
O
R
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
ISM SFM
1/4 2/3
Master/Local Module QJ61BT11
Name and Setting of Each Part
LED display
It is possible to check the data link condition by the on/off status of the
LED display.
RUN
ERR.
MST
S MST
LOCAL
CPU R/W
ERROR
L RUN
L ERR.
SD
RD
On: The module is normal.
On: Communication error for all stations
Flashing: There is a communication faulty station.
On: Set as the master station.
On: Set as the standby master station.
On: Set as a local station.
On: Communicating with the PLC CPU (FROM/TO).
Turns on at an error.
On: Performing data link
On: Communication error (self-station)
On: Sending data
On: Receiving data
LED name Description
Station number setting switches
These switches are used for setting the module's sta-
tion number.
Master station: 0
Local station: 1 to 64
Standby master station: 1 to 64
If the mode switch is set to remote I/O network mode,
the setting specifies the number of connected modules.
Mode setting switch
0
1
2
Online
(remote
network mode)
Online
(remote I/O
network mode)
Offline
Select this mode when
performing data link in the
remote network mode.
Select this mode when
performing data link in the
remote I/O network mode.
Data link is disconnected.
Number Name Description
This is used for setting the module's transmission speed and
operation mode.
Condition setting switch
SW1
SW5
SW6
SW8
1 station
2 stations*
3 stations*
4 stations
Off
On
On
Off
Off
Off
On
On
Number
of
occupied
stations
SW6SW5
Station type
Number of
occupied stations
Module mode
Off: Master/local station
On: Standby master station
Off: Intelligent mode
On: I/O mode
Number Setting Switch status
 Supported by hardware version F or later of the AJ61QBT11.
In cases other than the above, the number of occupied
stations is set by SW5 only.
Off: Occupies 1 station.
On: Occupies 4 stations.
Always set SW6 to off, as it is not used.
Terminal block
The CC-Link dedicated cable for performing data link is con-
nected here.
0
1
2
3
4
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps
Number Transmission speed
Transmission speed setting switch
This is used for setting the module's transmission speed.
External Dimension Diagram
Product
Description
Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection