Specifications

External Dimension Diagram
21
LED display
RUN
ERR.
MST
S MST
LOCAL
CPU R/W
ERROR
L RUN
L ERR.
B RATE
SD
RD
On: The module is normal.
On: Communication error for all stations
Flashing: There is a communication faulty station.
On: Set as the master station.
On: Set as the standby master station.
On: Set as a local station.
On: Communicating with the PLC CPU (FROM/TO).
Turns on at an error.
On: Performing data link
On: Communication error (self-station)
The LED corresponding to the transmission speed set
by the transmission speed setting switch turns on.
On: Sending data
On: Receiving data
LED name Description
0
1
2
3
4
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps
Number Transmission speed
Mode setting switch
0
1
2
Online
(remote
network mode)
Online
(remote I/O
network mode)
Offline
Select this mode when
performing data link in the
remote network mode.
Select this mode when
performing data link in the
remote I/O network mode.
Data link is disconnected.
Number Name Description
This is used for setting the module's transmission speed and
operation mode.
Station number setting switches
These switches are used for setting the module's station
number.
Master station: 0
Local station: 1 to 64
Standby master station: 1 to 64
If the mode switch is set to remote I/O network mode, the set-
ting specifies the number of connected modules.
Terminal block
The CC-Link dedicated cable for performing data link is con-
nected here.
Condition setting switch
SW1
SW4
SW5
SW6
1 station
2 stations*
3 stations*
4 stations
Off
On
On
Off
Off
Off
On
On
Number
of
occupied
stations
SW6SW5
Station type
Number of
occupied stations
Input data status
of data link
faulty station
Off: Master/local station
On: Standby master station
Off: Clear
On: Retain
 Supported by hardware version F or later of the AJ61QBT11.
In cases other than the above, the number of occupied
stations is set by SW5 only.
Off: Occupies 1 station.
On: Occupies 4 stations.
Always set SW6 to off, as it is not used.
Number Setting Switch status
Transmission speed setting switch
This is used for setting the module's transmission speed.
A
J61QBT11
0
5
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
STATION NO.
X10
X1
MODE
0:ONLINE(A.R.)
1:ONLINE(RIM)
2:OFFLINE
B RATE
0
1
2
3
4
156K
625K
2.5M
5M
10M
OFF
M/L
CLEAR
1/2
1/4
ON
S MST
HOLD
3/4
2/3
SW
1
2
3
4
5
6
7
8
ON
1
3
5
7
9
2
4
6
8
10
NC
DA
DB
DG
SLD
(FG)
NC
NC
NC
NC
RUN
ERR.
MST
S MST
LOCAL
CPU R/W
SW
M/S
PRM
TIME
LINE
L RUN
L ERR.
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
SD
RD
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
MODE
0:ONLINE(A.R.)
2:OFFLINE
1:ONLINE(RIM)
B RATE
0
1
2
3
4
156K
625K
2.5M
5M
10M
0
5
9
4
8
3
7
2
6
1
OFF
M/L
CLEAR
1/2
1/4
ON
S MST
HOLD
3/4
2/3
SW
1
2
3
4
5
6
7
8
ON
A
J61QBT11
RUN
ERR.
MST
S MST
LOCAL
CPU R/W
SW
M/S
PRM
TIME
LINE
L RUN
L ERR.
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
SD
RD






AJ61QBT11

1
3
5
7
9
2
4
6
8
10
NC
DA
DB
DG
SLD
(FG)
NC
NC
NC
NC
RUN
ERR.
MST
S MST
LOCAL
CPU R/W
SW
M/S
PRM
TIME
LINE
L RUN
L ERR.
156K
625K
2.5M
5M
10M
TEST
S0
S1
S2
SD
RD
0
5
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
STATION NO.
X10
X1
MODE
0:ONLINE(A.R.)
1:ONLINE(RIM)
2:OFFLINE
B RATE
0
1
2
3
4
156K
625K
2.5M
5M
10M
OFF
M/L
CLEAR
1/2
1/4
ON
S MST
HOLD
3/4
2/3
SW
1
2
3
4
5
6
7
8
ON
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
Unit: mm
Master/Local Module AJ61QBT11
Name and Setting of Each Part
Product
Description
Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection