Repeater Modules
● List of Models
If the module is used in
this way…?
Select this!
?
!
110
112
112
110
112
114
Selection condition
Page with detailed
information
Model name of the
module that should be selected
Feature of module that
should be selected
Selection of Repeater Modules
AJ65SBT-RPT
AJ65SBT-RPS
AJ65SBT-RPG
AJ65SBT-RPT
AJ65SBT-RPS
AJ65SBT-RPG
AJ65BT-RPI-10A
AJ65BT-RPI-10B
AJ65SBT-RPS
AJ65SBT-RPG
To extend the
transmission distance
To avoid problems due to noise
To use T-branches and
branching lines in
your network topology
To use CC-Link in a place where
cables cannot be laid
Select a module according to
the transmission distance
that can be used at all
transmission speeds.
T-branch wiring can be made
at all transmission speeds.
Wireless transmission (over
distances from 0 to 100 m) via
infrared light is made possible
(the maximum transmission
speed is 2.5 Mbps).
Through the use of optical
fiber cable, problems due to
noise can easily be avoided
and system stability improved.
Product name Model name Description
Number of
occupied
stations
Station type Related manual
Page with
detailed
information
● Precautions when Configuring the System
Maximum number of connected levels: 10,
T-branch wiring is possible.
Use AJ65BT-RPI-10A and AJ65BT-RPT-10B
as a set.Transmission speeds of 156 kbps,
625 kbps and 2.5 Mbps are supported.
Wireless transmission distances from 0 to
100 m via infrared light.Optical communication
status monitoring function
SI/QSI-type optical fiber cables are used
(combining and using two modules).
Maximum number of connected levels: 3,
maximum transmission distance: 500 m (SI)/
1000 m (QSI)
GI-type optical fiber cables are used
(combining and using two modules).
Maximum number of connected levels: 2,
maximum transmission distance: 2000 m
AJ65SBT-RPT
AJ65SBT-RPS
AJ65BT-RPI-10A
AJ65BT-RPI-10B
AJ65SBT-RPG
CC-Link system
repeater (T-branch)
module
CC-Link system
optical repeater
module
CC-Link system
wireless optical
repeater module
110
112
112
114
114
User's Manual
IB-0800078
(13JQ81)
―
―
―
―/1
―/1
■It is necessary to match the transmission speed of each segment to the transmission speed of the
master station.
User's Manual
IB-0800089
(13JQ85)
User's Manual
IB-0800090
(13JQ86)
―
―
―
Remote I/O station
when occupying
one station
Remote I/O station
when occupying
one station
Overview
Master/Local
Remote I/OAnalog
High-Speed
Counters
PositioningHMIRepeatersRS-232
Interfaces
OptionSoftwareOthers
Technical
Information
CC-Link
-
CC-Link / LT
Bridge Modules
Support PC
Interfaces
Peripheral
Device
Connection