Service manual
26
MUH-07RV -
MUH-09RV -
MUH-12RV -
Outdoor deicer P.C. board
E4
E4
E4
CN711
Outdoor fan motor
220-240V AC
CN721
R.V. coil
220-240V AC
F61
Fuse
2A/250V
}
}
CN661 1-2
Defrost thermistor RT61
}
12V DC
J204
J101
R601
5~10VDC
}
--
+
5V DC
J205
J101
--
+
--
+
Power supply input
220-240V AC
}
NR61
Varistor
Jumper wire for
change in
defrost setting
(JRF,JRG)
(Refer to page
5.)
}
Defrost interval
time short pin
(JPDS, JPSG)
(Refer to page 5.)
OB252C-1.qxp 02.4.25 11:28 AM Page 26