Unit installation
4-way Ceiling Cassette
10
09
4-way Ceiling Cassette
PLA
SERIESSERIES
Advancements in PLA Series improve
style and performance for ensured
indoor comfort
Wide Airflow
Wide-angle outlets distribute airflow to all cor-
ners of the room, ensuring the room is suffi-
ciently cooled/heated. Horizontal airflow and a
fan speed reduced by 20% compared to con-
ventional models also contribute to increased
comfort for occupants.
Conventional model
PLA-RP
✽ ✽
BA
Less Cold Draft
The “Horizontal Airflow” function pre-
vents cold drafts from striking the body
directly, thereby keeping the body from
becoming over-chilled.
Horizontal Airflow
prevents drafty feeling
Independent Vane Direction
Setting
Use the wired remote controller to set
the airflow pattern of each vane inde-
pendently. Easily adjust airflow to the in-
terior layout and seasonal conditions,
and ensure an even temperature distri-
bution all the time.
Using wired remote controller,
set airflow direction for each vane
(
manual setting also possible
)
Settings can be changed anytime
using a wired remote controller.
Vertical
flow
Horizontal
flow
Set by remote
controller
Fixed
Temperature gap with uneven
temperature distribution
Temperature gap is minimised,
and room is warmed uniformly
Swing mode
Vertical flow
Wave Airflow Mode for Heating
The airflow direction at
each outlet changes inter-
mittently, providing a con-
sistent temperature through-
out the room.
Vertical
flow
Vertical
flow
Vertical
flow
Vertical
flow
Simultaneous horizontal and vertical operation ensure
a comfortable room from corner to corner
● “Wave Airflow” operation image
● Wave control effect thermograph
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby maintaining a com-
fortable room environment at all times. At the start of operation, a high
fan speed realises quick heating/cooling of the room. Once the
desired temperature is reached, the fan speed is reduced for stable
heating/cooling and greater comfort.
HiLo AutoMi1 Mi2
Fan speed setting by remote controller
(
four levels
)
✽Special setting is required for wireless remote controller.
Quiet Operation
An improved airflow path and powerful high-
capacity flow fan contribute to the realisation of
quieter operation.
Power flow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller
express a clean, streamlined image that is a suitable match for any
interior.
Other Features
•
Stylish indoor-unit vane covers (when unit is turned off)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for Fresh-air Intake
• Branch duct
Automatic Grille Lowering
Function
(
Option
)
Easy to use/Simple maintenance
An automatic grille lowering
function capable of stopping
at eight different heights is
available to simplify filter main-
tenance.
✽ A receiver on the elevated panel
detects commands from the
wireless remote controller.
Wired remote
controller
(optional for Auto
Elevating Panel)
Elevating (up-down)
controller
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
four metres
4-way cassettes can be equipped with the i-see Sensor,
a radiation-based sensor that monitors floor-level
temperatures throughout the room to
ensure room comfort.
i-see Sensor works to
ensure even temperature
distribution and save
energy (requires optional
corner panel)
i-see Sensor improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a
radiation-based sensor to monitor temperature throughout the entire room.
When connected to the air conditioner control panel, i-see Sensor works to
maximise room comfort through 360° sensing that covers the whole floor space.
The i-see Sensor rotates 90° and takes 5-second
measurements to accurately determine floor-level
temperatures on all sides of the room.
■ i-see Sensor Operation
● The i-see Sensor calculates the temperature by measuring the infrared rays emanating
from the walls and floors, and measuring the floor-level temperature.
● The sensor rotates 360-degrees once every two minutes when there is significant tem-
perature disparity and once every five minutes when a stable, even temperature has been
reached.
90°
rotation
90°
rotation
90°
rotation
5sec
measurement
5sec
measurement
5sec
measurement
5sec
measurement
360°
Floor-level temperature
measured throughout the room.
2.7m
Set temperature: 20°C
with i-see Sensor + Auto Fan Speed
Without i-see Sensor
With i-see Sensor
Area which the
“i-see Sensor”
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
Set temperature: 23°C
without i-see Sensor
37°C
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature
and the floor temperature. This technology makes it possible to avoid overcool-
ing or overheating.
sensing
11.5m
2.7m
sensing
11.5m
25°C
13°C
37°C
25°C
13°C
Heating Heating
2.7m
Area which the
i-see Sensor
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
360°360°
sensing
11.5m
2.7m
sensing
11.5m
Only intake-air temperature at the
ceiling is measured, resulting in
uneven temperature distribution.
Both floor-level and intake-air tem-
peratures are measured, providing op-
eration that creates a comfortable
room environment from ceiling to floor.
Indoor unit
Specifications: 4-way ceiling cassette
(
PLA
)
PLA-RP60BA
PLA-RP60BA
SU Z-K A6 0VA 2
Cooling Heating
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
Indoor unit
Power supply
Airflow
(
Lo-Mi2-Mid-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
CMM
PL A-RP71BA
PL A-RP71BA
12-14-16 -18 14-16 -18-21
200-233-267-300 233-267-300-350
28-29-31-32 28-30-32-34
SU Z-K A71VA 2
Cooling Heating
6.1 (1.1-6. 3 ) 6.9 (0.9-8.0) 7.1 ( 0. 9 -8 .1) 8.0 (0.9-10.2)
1.87 1.97 2.07 2.19
3.26 3.50 3.43 3.65
PL A-RP71BA
PL A-RP71BA
14-16 -18 -21
233-267-300-350
28-30-32-34
PUHZ-RP71VHA3
Cooling Heating
PL A-RP100BA
PL A-RP100BA
20-23-26-30
334-384-434-501
32-34-37-40
Unit: 25, Panel: 6
22-25-28-31
367-417-4 67- 517
34-36-39-41
Unit: 840, Panel: 950
Unit: 298, Panel: 35
Unit: 840, Panel: 950
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 27, Panel: 6
PUHZ-RP100V/YHA2
Cooling Heating
PLA-RP125BA
PLA-RP125BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Unit: 258, Panel: 35
Unit: 840, Panel: 950
Unit: 840, Panel: 950
Unit: 23, Panel: 6
PUHZ-RP125V/YHA2
Cooling Heating
PL A-RP140BA
PL A-RP140BA
PUHZ-RP140V/YHA2
Cooling Heating
14.0 (5.5-15.3)
4.65
3.01
16.0 (5.0-18.0)
4.43
3.61
12.5 (5.5-14.0)
3.87
3.23
14.0 (5.0-16.0)
3.88
3.61
10.0 (4.9-11.4)
3.02
3.31
11.2 (4.5-14.0)
3.10
3.61
2.09
3.40
2.17
7.1 ( 3 .3 - 8.1 ) 8.0 (3.5 -10. 2)
3.69
PLA-RP60/71
100/125/140BA
(
i-see Sensor: optional
)