Specifications

4Way Ceiling Cassette
The fan speed is changed automatically depending on the gap be-
tween set temperature and room temperature. In case of cooling,
operation starts with ‘Hi’ fan speed and once the room temperature
gets stable, the fan speed automatically decreases to low level for
more comfort.
Auto Fan Speed Mode
Our new PL Series have beautiful pure white coloured panel and wired
remote controller. A great match for interior appointments, generating
a clean and streamlined look.
“Pure White” Colour
Stylish vane shutter
(
when the unit is off
)
Drain up max. 850mm
Wireless remote controller available
Duct flange for fresh air intake (option)
Other Features
Easy to use, easy for maintenance.
With 8 levels to fit all ceiling heights.
Filter cleaning and other maintenance
can be operated easily.
Automatic Elevating Panel (option)
The receiver on the elevating
panel can be used for wire-
less remote controller.
Thanks to the improvement of airflow route and
large caliber power flow fan, we can realize quiet
operation.
Quiet Operation
Power Flow Fan
HiLo AutoMi1 Mi2
Fan speed setting by remote controller
(
4 levels
)
Special setting is required for wireless remote controller.
Wired remote
controller
(optional for Auto
Elevating Panel)
Elevating (up-down)
controller
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
The newly developed 4Way Ceiling Cassette can be
equipped with the radiant temperature sensor,
“i-see Sensor” to ensure comfort
of the room.
“i-see Sensor” is bad
news for temperature
disparity and electric bill
waste (optional corner
panel
)
The radiant temperature sensor “i-see Sensor” for your comfort
The “i-see Sensor,” a radiant temperature sensor built from new concept engin-
eering available only at Mitsubishi. The control of the floor temperature at foot
level is required to realize a comfortable air conditioning in your office or shop.
The “i-see Sensor” measures floor temperature with rotating 360° and provides
you the comfort which you have not ever experienced.
Operates at 5-second interval for precision measurement,
and checking the temperature of the floor.
“i-see Sensor” operation image
The “i-see Sensor” detects infrared rays emanating from the walls and floor. The tempera-
ture is calculated basis on infrared ray energy. It makes it possible to check the radiant
temperature (the floor temperature).
Upon big gap with the set temperature, measurements are taken at 4 points every 2 min-
utes. Once stabilized, the sensor revolves once every 5 minutes.
90°
revolution
90°
revolution
90°
revolution
5-second
measurements
5-second
measurements
5-second
measurements
5-second
measurements
360°
The “i-see Sensor” revolves
for detailed floor temperature readings.
Automatic
elevation to
4 meters
2.7m
Set temperature: 20°C
with “i-see Sensor”+Auto Fan Speed
The conventional model only
measured and monitored indoor
temperature near the ceiling.
As the current packaged air condi-
tioners only monitor temperature
levels near the ceiling, they fail to
detect vertical between ceiling and
floor temperature gaps.
Besides the ceiling zone, the floor
temperature are also checked to
keep the room comfortable.
New PL Series (with “i-see Sen-
sor”) naturally measures indoor tem-
perature and floor temperature with-
out any timelag.
Area which the
“i-see Sensor”
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
Set temerature: 23° C
without “i-see Sensor
37°C
“I feel” Temperature Control
The sensory temperature is calculated by measuring the air intake temperature
and the floor temperature. This technology makes it possible to avoid overcool-
ing or overheating.
360°
sensing
11.5m
2.7m
360°
sensing
11.5m
25°C
13°C
37°C
25°C
13°C
Heating Heating
2.7m
Area which the
“i-see Sensor”
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
360°
sensing
11.5m
2.7m
360°
sensing
11.5m
NEW
PLA-RP71BA PLA-RP100BA PLA-RP100BA
PLA-RP71BA PLA-RP100BA PLA-RP100BA
PUHZ-RP71VHA2 PUHZ-BP100VHA PUHZ-RP100V/YHA2
Cooling Heating Cooling Heating Cooling Heating
7.1
(
3.3-8.1
)
8.0
(
3.5-10.2
)
9.4
(
3.5-10.0
)
9.5
(
3.5-11.2
)
10.0
(
4.9-11.4
)
11.2
(
4.5-14.0
)
2.12 2.21 3.13 2.46 3.10
3.35
Unit: 25, Panel: 6
Unit: 298, Panel: 35
32-34-37-40
14-16-18-21
233-267-300-350
20-23-26-30
334-384-434-501
3.61 3.01 3..86
PLA-RP71BA
SUZ-KA71VA
Cooling Heating
3.31 3.61
3.94 3.64
2.84 3.44
PLA-RP125BA
PLA-RP125BA
PUHZ-BP125VHA
Cooling Heating
11.2
(5
.5-12.5
)
12.5
(4.7
-14.0
)
34-36-39-41
22-25-28-31
367-417-467-517
3.87
3.88
3.23 3.61
PLA-RP125BA
PLA-RP125BA
PUHZ-RP125V/YHA2
Cooling Heating
12.5
(
5.5-14.0
)
14.0
(
5.0-16.0
)
5.28 4.24
2.46 3.49
PLA-RP140BA
PLA-RP140BA
PUHZ-BP140VHA
Cooling Heating
13.0
(
5.2-14.5
)
14.8
(
4.7-16.0
)
Unit: 27, Panel: 6
36-39-42-44
24-26-29-32
400-434-484-534
4.65 4.43
3.01 3.61
PLA-RP140BA
PLA-RP140BA
PUHZ-RP140V/YHA2
Cooling Heating
14.0
(
5.5-15.3
)
16.0
(
5.0-18.0
)
Unit: 258, Panel: 35
Unit: 840, Panel: 950
Unit: 840, Panel: 950
3.02
7.1
(
0.9-8.1
)
2.53
2.81
8.0
(
0.9-10.2
)
2.49
3.21
Single phase, 50Hz, 220-240V
28-30-32-34
Unit: 23, Panel: 6
PLA-RP71BA
NEW