Specifications

Notes for application:
* Check the lineset sizes for your indoor selected models.
* Select the branch box or boxes needed for your application.
* Compare indoor unit lineset sizes to branch box or outdoor
unit port sizes.
* Connect 15K + indoor units to the larger 1/2" port on the
PAC-AKA51BC branch box or outdoor unit.
* Adapt lineset size with appropriate port adapter from above list.
* When using the PLA-A24BA4, PEAD-A24AA4, PCA-A24KA4 MSZ-FE18NA
or MSZ-GE24NA two port adapters will be needed
1-MAC-A456JP-E (1/2" x 5/8") or 1-PAC-SG76RJ-E (3/8" x 5/8") and
1-PAC493PI (1/4" x 3/8").
MXZ-2B20NA-1
Port A = 3/8" gas x 1/4" liquid
Port B = 3/8" gas x 1/4" liquid
MXZ-3B24NA-1
Port A = 1/2" gas x 1/4" liquid
Port B = 3/8" gas x 1/4" liquid
Port C = 3/8" gas x 1/4" liquid
MXZ-3B30NA-1
Port A = 1/2" gas x 1/4" liquid
Port B = 3/8" gas x 1/4" liquid
Port C = 3/8" gas x 1/4" liquid
MXZ-4B36NA-1
Port A = 1/2" gas x 1/4" liquid
Port B = 3/8" gas x 1/4" liquid
Port C = 3/8" gas x 1/4" liquid
Port D = 3/8" gas x 1/4" liquid
MXZ-8B48NA
Branch Box Branch Box
PAC-AKA31BC PAC-AKA51BC
PORT A = 3/8" gas x 1/4" liquid PORT A = 3/8" gas x 1/4" liquid
PORT B = 3/8" gas x 1/4" liquid PORT B = 3/8" gas x 1/4" liquid
PORT C = 3/8" gas x 1/4" liquid PORT C = 3/8" gas x 1/4" liquid
PORT D = 3/8" gas x 1/4" liquid
PORT E = 1/2" gas x 1/4" liquid
21