Specifications
17
MSZ WALL-MOUNTED INDOOR UNITS
(FOR MXZ-2A20/3A30/4A36NA OUTDOOR UNITS)
INVERTER
Model Name
Indoor Unit MSZ-A09NA MSZ-FD09NA MSZ-A12NA MSZ-FD12NA MSZ-A15NA MSZ-A17NA MSZ-A24NA
Outdoor Unit For Use with all MXZ-Series
Cooling *1
Rated Capacity Btu/h 9,000 9,000 12,000 12,000 15,000 16,200 22,000
Total Input W 16 18 21 24 30 30 53
Heating at 47º F *2
Rated Capacity Btu/h 10,900 10,900 13,600 13,600 18,000 20,100 23,200
Total Input W 16 24 21 30 30 30 53
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208 / 230V *4
Voltage
Indoor - Outdoor S1-S2 AC 208-230V
Indoor - Outdoor S2-S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC12V)
MCA *4 A 1.0
Fan
Fan Motor F.L.A. 0.76
Airflow (Cool)
(Lo-Med-Hi) *1
DRY (CFM) 152-229-307 162-226-339 152-240-353 162-226-381 268-328-381 296-431-568
WET (CFM) 134-205-275 144-202-307 134-215-318 144-202-350 240-293-342 265-385-508
Airflow (Heat) (Lo-Med-Hi) *2 DRY (CFM) 159-222-307 166-240-367 159-240-353 166-240-399 254-314-381 296-486-568
Sound Pressure Level (Cooling) (Lo-Med-Hi) *1
dB(A)
22-33-38 22-31-39 22-34-42 22-33-43 34-40-45 34-40-46 34-40-49
Sound Level Pressure
(Heating) (Lo-Med-Hi) *2
22-33-38 22-31-40 22-34-42 22-33-43 34-38-44 34-40-48
External Finish Color Munsell No. 1.0Y 9.2/0.2
Dimension
W: In. 30-11/16 31-7/16 30-11/16 31-7/16 30-11/16 43-5/16
D: In. 8-1/4 10-1/8 8-1/4 10-1/8 8-1/4 10-1/4
H: In. 11-3/4 11-5/8 11-3/4 11-5/8 11-3/4 12-13/16
Weight Lbs. 23 27 23 27 23 37
Field Drainpipe Size In. O.D.: 5/8
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant Type R410A
Refrigerant Pipe
Gas Side O.D.
In.
3/8 1/2 5/8
Liquid Side O.D. 1/4
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
For data on specific indoor unit combinations, see pages 21 to 23.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
SEZ DUCTED INDOOR UNIT
(FOR MXZ-2A20/2B20/3A30/4A36NA OUTDOOR UNITS)
INVERTER
Model Name
Indoor Unit SEZ-KD09NA SEZ-KD12NA SEZ-KD15NA SEZ-KD18NA
Outdoor Unit For Use with all MXZ-Series
Cooling *1
Rated Capacity Btu/h 9,000 12,000 15,000 17,200
Total Input W 60 70 90
Heating at 47˚ F *2
Rated Capacity Btu/h 10,900 13,600 18,000 20,100
Total Input W 40 50 70
Power Supply Phase, Cycle, Voltage 1-Phase, 60Hz, 208 / 230V *4
Voltage
Indoor - Outdoor S1-S2 AC 208- 230V
Indoor - Outdoor S2-S3 DC24V
MCA *4 A 1.0
Fan
Fan Motor Output W 96
Airflow (Lo-Med-Hi) CFM 194-247-317 247-317-388 353-441-529 423-529-635
External Static Pressure *3 In.W.G. 0.02-0.06-0.14-0.20
Sound Pressure Levels (Lo-Med-Hi) dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
External Finish Galvanized-steel Sheets
Dimension
W: In. 31-1/8 39 46-7/8
D: In. 27-9/16
H: In. 7-7/8
Weight Lbs. 40 46 51 60
Drain Lift Mechanism (Included) H: In. 21-11/16
Field Drainpipe Size In. O.D.: 1-1/4
Remote Controller Type Wired Controller (PAR-21MAA)
Refrigerant Type R410A
Refrigerant Pipe
Gas Side O.D.
In.
3/8 1/2
Liquid Side O.D. 1/4
Connection Method Flared/Flare
Notes:
*1 Cooling-Indoor: D.B. 80º F (26.7º C),
W.B. 67º F (19.4º C); Outdoor: D.B. 95º F
(35º C), W.B. 75º F (23.9º C).
*2 Heating-Indoor: D.B. 70º F (21.1º C),
W.B. 60º F (15.6º C); Outdoor: D.B. 47º F
(8.3º C), W.B. 43º F (6.1º C).
*3 External static pressure is factory
set to 0.06" W.G. Adjustable via the
PAR-21MAA
*4 Indoor units receive power
from outdoor units through field-
supplied interconnected wiring.
Specifications are subject to change
without notice.
LIMITED WARRANTY Seven-year
warranty on compressor. Five-year
warranty on parts.
**For data on specific indoor unit
combinations, see page 21 - 23