Service manual
5
3
SPECIFICATION
Indoor model MSZ-FD09NA MSZ-FD12NA
Power supply V, phase, Hz 208/230 , 1 , 60
Max. fuse size (time delay)/ Disconnect switch
A15
Min. circuit ampacity A 1.0
Fan motor F.L.A 0.76
Airfl ow
Low - Med. - High - Powerful
COOL Dry
(Wet)
CFM
162 - 226 - 339 - 381
(144 - 202 - 307 - 343)
162 - 226 - 381 - 410
(144 - 202 - 350 - 367)
HEAT Dry CFM 166 - 240 - 367 - 381 166 - 240 - 399 - 420
Moisture removal pt./h 2.1 2.9
Sound level
Low - Med. - High - Powerful
Cooling dB(A) 22 - 31 - 39 - 42 22 - 33 - 43 - 45
Heating dB(A) 22 - 31 - 40 - 42 22 - 33 - 43 - 44
Cond. drain connection O.D. in. 5/8
Dimensions
W
in.
31-13/32
D 10-1/8
H 11-5/8
Weight Ib. 27
External fi nish Munsell 1.0Y 9.2/0.2
Remote controller Wireless type
Control voltage (by built-in transformer) 12 - 24 VDC
NOTE: Test conditions are based on ARI 210/240.