Quick start manual
d
Sup ply 24 V DC ±10 % 150 mA cur rent for in ter faces from the out side. 150 mA is the value
ap pli ca ble when all I/O sig nals are used. The cur rent ca pac ity can be de creased by re duc ing
the num ber of I/O points.
e
When start ing op er a tion, al ways turn on forced stop (EMG) and For ward/Re verse ro ta tion
stroke end (LSP/LSN). (Nor mally closed con tacts)
f
Trou ble (ALM) turns on in nor mal alarm-free con di tion.
g
Use MRZJW3-SETUP 211E.
h
Per sonal com put ers or pa ram e ter mod ules can also be con nected via the CN3 con nec tor,
en abling RS422 com mu ni ca tion. Note that us ing the USB com mu ni ca tion func tion (CN5
con nec tor) pre vents the RS422 com mu ni ca tion func tion (CN3 con nec tor) from be ing used,
and vice versa. They can not be used to gether.
i
For the sink I/O in ter face.
Additional Connections Positioning via a CC-Link Network
5 - 32 MITSUBISHI ELECTRIC
Personal computer
MR-PRU03
parameter module
RS232C/RS422 conversion cable
Servo amplifier
EIA568-compliant cable (10BASE-T cable, etc.)
To RS232C connector
or