Exam ples:
a
The Z-phase of the en coder is de fined as the phys i cal home po si tion of the ma chine. In this
ex am ple we are go ing to per form the home po si tion re turn at 200 rpm in the di rec tion in
which the en coder pulses are counted incrementally.
Param e ter set tings:
Positioning with Digital Inputs Home Position Return
MR-J3-T 4 - 17
Fig. 4-6: Rel e vant pa ram e ter set tings for ex am ple 1
2
1
Pa ram e ter set tings for ex am ple
Fig. 4-7: Val ues shown when the home po si tion re turn has
been com pleted cor rectly