Instruction manual

12 - 19
12. OPTIONS AND AUXILIARY EQUIPMENT
(b) Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in the
regenerative mode.
Servo amplifier Inverse efficiency[%] Capacitor charging[J]
MR-J3-10A 55 9
MR-J3-10A1 55 4
MR-J3-20A 70 9
MR-J3-20A1 70 4
MR-J3-40A 85 11
MR-J3-40A1 85 10
MR-J3-60A 85 11
MR-J3-70A 80 18
MR-J3-100A 80 18
MR-J3-200A 85 40
MR-J3-350A 85 40
MR-J3-500A 90 45
MR-J3-700A 90 70
Inverse efficiency ( ) :Efficiency including some efficiencies of the servo motor and servo amplifier
when rated (regenerative) torque is generated at rated speed. Since the
efficiency varies with the speed and generated torque, allow for about 10%.
Capacitor charging (Ec) :Energy charged into the electrolytic capacitor in the servo amplifier.
Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies by the
inverse efficiency to calculate the energy consumed by the regenerative brake option.
ER [J]
Es Ec
Calculate the power consumption of the regenerative brake option on the basis of single-cycle operation period
tf [s] to select the necessary regenerative brake option.
PR [W]
ER/tf .............................................................................................(12.1)
(3) Connection of the regenerative brake option
Set parameter No. PA02 according to the open to be used.
Parameter No. PA02
Selection of regenerative
00: Regenerative brake option is not used
For MR-J3-10A, regenerative brake resistor is not used.
For MR-J3-20A, built-in regenerative brake resistor is used.
01: MR-BU MR-RC
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50
08: MR-RB31
09: MR-RB51