Instruction manual

12 - 13
12. OPTIONS AND AUXILIARY EQUIPMENT
(4) MR-J3ENSCBL M-L MR-J3ENSCBL M-H
These cables are detector cables for HF-SP Series servomotors. The number in the cable length column of
the table indicates the symbol filling the square
in the cable model. Cable lengths corresponding to the
specified symbols are prepared.
Cable Length
Cable Model
2m
(6.56ft)
5m
(16.4ft)
10m
(32.8ft)
20m
(65.6ft)
30m
(98.4ft)
40m
(131ft)
50m
(164ft)
Protective
Structure
Flex Life Application
MR-J3ENSCBL
M-L
2 5 10 20 30 IP67 Standard
MR- J3ENSCBL
M-H
2 5 10 20 30 40 50 IP67 Long flex
For HF-SP servo motor
(a) Connection of servo amplifier and servo motor
Servo amplifier
1)
2)
MR-J3ENSCBL M-L
MR-J3ENSCBL M-H
CN2
Servo motor
HF-SP
Cable Model 1) For CN2 Connector 2) For Encoder Connector
MR-J3ENSCBL
M-L
Receptacle: 36210-0100JL
Shell kit: 536310-3200-008
(3M or equivalent)
View seen from wiring side.
(Note) Signal layout
4
2
LG
8
MDR
6
1
P5
5
10
3
MR
7
MD
9
BAT
MRR
MR-J3ENSCBL
M-H
Note. Keep open the pins shown with
. Especially, pin 10 is provided for
manufacturer adjustment. If it is connected with any other pin, the
servo amplifier cannot operate normally.
In case of 10m or shorter cables
Straight plug: CM10-SP10S-M
Socket contact: CM10-
#22SC(C1)-100
Crimping tool: 357J-50446
(DDK)
Applicable cable AWG20 to 22
In case of 20m or longer cables
Straight plug: CM10-SP10S-M
Socket contact: CM10-
#22SC(C2)-100
Crimping tool: 357J-50447
(DDK)
Applicable cable AWG23 to 28
1
MR
2
MRR
3
5
LG
4
BAT
7 6
10
SHD
9 8
P5
(Note) Signal layout
View seen from wiring side
Note. Keep open the pin shown
with an
.