Instruction manual
5 - 9
5. PARAMETERS
To rotate the servo motor at 3000r/min in the open collector system (200kpulse/s), set the electronic gear
as follows
CDV
CMX
N
0
f
60
pt
f : Input pulses [pulse/s]
N
0
: Servo motor speed [r/min]
Pt : Servo motor resolution [pulse/rev]
200
60
CDV
CMX 3000
262144
CDV
CMX
3000
60
262144
200
60 200000
3000
262144 8192
125
10
3
10
3
The following table indicates the electronic gear setting example (ballscrew lead 10mm) when the
QD75 is used in this way.
Rated servo motor speed 3000r/min 2000r/min
Input system
Open
collector
Differential
line driver
Open
collector
Differential
line driver
Max. input pulse frequency [pulse/s] 200k 1M 200k 1M
Feedback pulse/revolution [pulse/rev] 262144 262144
Servo amplifier
Electronic gear (CMX/CDV) 8192/125 8192/625 16384/375 16384/1875
Command pulse frequency [kpulse/s] (Note) 200k 1M 200k 1M
Number of pulses per servo motor revolution as viewed
from QD75[pulse/rev]
4000 20000 6000 30000
AP1111
AL1111
Minimum command unit
1pulse
AM1111
AP 4000 20000 6000 30000
AL 100.0[ m] 100.0[ m] 100.0[ m] 100.0[ m]
AD75P
Electronic gear
Minimum command unit
0.1
m
AM 10 10 10 10
Note. Command pulse frequency at rated speed
POINT
In addition to the setting method using the electronic gear given here, the
number of pulses per servo motor revolution can also be set directly using
parameter No. PA05. In this case, parameter No. PA05 is the "Number of
pulses per servo motor revolution as viewed from QWD75".