Specifications

8-15
9) Dog cradle type home position return
Timing chart for dog type (front end detection) home position return
Servo-on (SON)
Ready (RD)
Trouble (ALM)
Point No. selection (DI0, DI1)
Automatic/manual selection (MD0)
In position (INP)
Rough match (CPO)
Home position return
completion (ZP)
Motor speed
Z-phase pulse
Dog input signal(DOG)
Forward rotation start (ST1)
Reverse rotation start (ST2)
Point No. output (PT0, PT1)
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ONON
ON
ON
ONON
ON
ON
ON
Home position shift distance
Home position address
Proximity dog
Home position return speed
Cree
p
s
p
eed
5ms or less
5ms or more
No.0
No.0Indefinite
8ms or more
A home position return can also be started
anywhere along the dog. The axis moves in
the direction opposite to the home position
return direction, returns to the front end of
the dog, and decelerates to a stop.
After that, an ordinary home position return
is performed automatically.
A home position return can also be started
anywhere past the dog.
In this case, the axis moves in the home
position return direction once. When the limit
switch is actuated, the rotation direction is
reversed, and the axis returns to the front end
of the dog and decelerates to a stop.
After that, an ordinary home position return is
performed automatically.
Note: When the dog cannot be detected during
a home position return from the position
past the dog, the axis stops at the limit
switch located in the direction opposite to
the home position return direction.
The software limit is invalid for a home
position return.
Home position
Home position return
start position
Proximity dog
Home position
Home position return
start position
Proximity dog
Home position
return direction
Home position
return direction
Limit
switch