Specifications
8-3
Auxiliary function setting "0" or "2"
Auxiliary function setting "1" or "3", dwell time "0"
When the auxiliary function setting is "1" or
"3" and the dwell time setting is "0", the
acceleration/deceleration time constant is that
of the selected point table No.
In the diagram shown on the left, operation is
performed using the time constant of point
table No. 1.
Auxiliary function setting "1" or "3", dwell time "100"
When the auxiliary function setting is "1" or
"3" and the dwell time setting is "100", the
acceleration/deceleration time constant is that
of the selected point table No. being executed.
In the diagram shown on the left, operation of
point table No. 1 is performed using the time
constant of 1, and operation of point table No.
2 is performed using the time constant of 2.
Speed
Point table Point table
No. 1 No. 2
Start signal
Speed
Point tabl e Point ta bl e
No. 1 No. 2
Start signal
Speed
Point tabl e Point tab le
No. 1 No. 2
Dwell
Start signal time