Specifications

8-1
8. OPERATION MODES
(1) Positioning operation with point table specified by device designation
1) Parameter setting items
Using parameter No. 00 (STY), select the absolute value command or incremental value command.
Setting Positioning System
0
Absolute value
command
1
Incremental value
command
Using parameter No. 01 (FTY), set the rotation direction of the start signal based on the forward rotation
start signal (ST1).
Setting Rotation Direction
0 CCW rotation with address increase
1 CW rotation with address increase
Using parameter No. 01 (FTY), set the instruction unit.
Setting Instruction Unit Travel
0 1-time pulse selection 1[ m]
1 10-time pulse selection 10[ m]
2
100-time pulse
selection
100[
m]
3
1000-time pulse
selection
1000[
m]