Specifications
6-6
Movement
finish output
MEND
Movement finish output device.
MEND-SG conduct when the in position output and rough match signals are output.
Point No. output
PT0
PT1
PT2
PT3
PT4
Point No. output devices.
The point table No. is output at completion of positioning.
The terminals are all open at power-on, at servo-off, during home position return or
at completion of home position return.
The previous output state is maintained when Automatic/manual mode selection
(MD0) is switched from the automatic mode to the manual mode, switched from the
manual mode to the automatic mode, during manual operation, or during high-speed
home position return.
PT4 PT3 PT2 PT1 PT0 Output Point Table No.
Open Open Open Open Open
Open Open Open Open Conduct Point Table No. 1
Open Open Open Conduct Open Point Table No. 2
Open Open Open Conduct Conduct Point Table No. 3
Open Open Conduct Open Open Point Table No. 4
Open Open Conduct Open Conduct Point Table No. 5
to to to to to to
Conduct Conduct Open Conduct Conduct Point Table No. 27
Conduct Conduct Conduct Open Open Point Table No. 28
Conduct Conduct Conduct Open Conduct Point Table No. 29
Conduct Conduct Conduct Conduct Open Point Table No. 30
Conduct Conduct Conduct Conduct Conduct Point Table No. 31