Specifications

4-2
Item Specifications
Count type
(Front end
detection)
Home position return is made with reference to the front end of the
proximity dog.
Home position address can be set.
Home position shift distance can be set.
Home position return direction can be selected.
On-dog automatic retraction home position return
Stroke automatic retraction function
Operation mode
Manual home
position return
mode
Dog cradle type
Home position return is made using the first Z-phase pulse with reference
to the front end of the proximity dog.
Home position address can be set.
Home position shift distance can be set.
Home position return direction can be selected.
On-dog automatic retraction home position return
Stroke automatic retraction function
Position control function
Absolute position detection
Backlash compensation
Software stroke limit