Specifications
3-44
Instruction
Code
Instruction Write Data (RW
w3
) Contents (PLC to Servo amplifier)
8F00
to 8F1F
Writes the point
table deceleration
time constant data
to EEPROM
Writes the deceleration time constant data of point table No. 00 to
31 to the EEPROM. Since the data is written to the EEPROM, the
setting is saved if power is switched off.
Deceleration time constant data: Make setting after
conversion into hexadecimal.
The under 2 digits (8F
) of the instruction code No. correspond to
the point table No. converted into decimal.
Instruction
Code
Instruction Data Details (Master to Servo Amplifier)
9000
to 901F
Writes the point
table dwell time
data to EEPROM
Writes the dwell time data of point table No. 00 to 31 to the
EEPROM. Since the data is written to the EEPROM, the setting is
saved if power is switched off.
Dwell time data: Make setting after conversion into
hexadecimal.
The under 2 digits (90
) of the instruction code No. correspond to
the point table No. converted into decimal.
Instruction
Code
Instruction Data Details (Master to Servo Amplifier)
9100
to 911F
Writes the point
table auxiliary
function data to
EEPROM
Writes the auxiliary function data of point table No. 00 to 31 to the
EEPROM. Since the data is written to the EEPROM, the setting is
saved if power is switched off.
Auxiliary function data: Make setting after conversion
into hexadecimal.
The under 2 digits (91
) of the instruction code No. correspond to