Specifications

3-19
2) When two stations are occupied
Monitor 1 code
(RWw0)
Monitor 2 code
(RWw1)
Monitor execution
demand (RY8)
Monitoring
(RX8)
Monitor 1 data
Under 16 bits
(RWr0)
Monitor 1 data
Upper 16 bits
(RWr1)
Monitor 2 data
Under 16 bits
(RWr5)
Monitor 2 data
Upper 16 bits
(RWr6)
Answer code
(RWr2)
Data held
Set monitor codes to Monitor 1 (RWw0) and Monitor 2 (RWw1), and turn on Monitor output execution
demand (RY8). Turning on RY8 sets the following data. For all 32-bit data, set the upper 16 bits and
under 16 bits separately to the registers. Data are all in hexadecimal. At this time, Monitoring (RX8)
turns on simultaneously.
Monitor data 1 under 16 bits (RWr0): Under 16 bits of data demanded by Monitor 1 (RWw0)
Monitor data 1 upper 16 bits (RWr1): Upper 16 bits of data demanded by Monitor 1 (RWw0)
Monitor data 2 under 16 bits (RWr5): Under 16 bits of data demanded by Monitor 2 (RWw1)
Monitor data 2 upper 16 bits (RWr6): Upper 16 bits of data demanded by Monitor 2 (RWw1)
If data does not exist at RWr1/RWr6, a sign is set. "
" indicates "0000" and " " "FFFF".
The monitor data set to the registers are continuously updated while RX8 is on. When RX8 turns off, the
data set to Monitor data RWr0, RWr1, RWr5, RWr6 are held.
If the monitor code set to either or both of Monitor 1 (RWw0) and Monitor 2 (RWw1) does not exist in the
specifications, an error code (
1) is set to Answer code
.