Expansion parameters 2
68 *CDP Gain changing selection
Select the gain changing selection condition.
0000 Refer to
name and
function
column.
69 CDS Gain changing enable range
Set the range where the changing ratios set in parameter
No. 67 to No. 69 are enabled.
Select the command frequency/droop pulses/model speed by
setting parameter No. 65.
10 kpps
pulse
r/min
0 to 9999
70 CDT Gain changing time constant
Set the time constant at which the gains change relative to the
conditions set in parameter No. 68, 69.
1 msec 0 to 100
71 VPI For manufacturer setting 100
72 VLI For manufacturer setting 10000
73 ERZ For manufacturer setting 10
74 ER2 For manufacturer setting 10
75 SRT For manufacturer setting 100
76 TRT For manufacturer setting 100
77 DBT For manufacturer setting 100
Note: After setting the values of the parameters marked *, switch power off once. Switching power on again
completes the setting.
Gain changing selection
0: Invalid
1: Input signal (CDP) (valid when on)
2: Command frequency (valid when more)
3: Droop pulses (valid when more)
4: Model speed (valid when more)