Specifications
10-7
Class No.
Abbrev-
iation
Name and Function
Initial
Value
Unit
Setting
Range
Basic parameters
16 *BPS Communication speed/communication I/F selection, alarm
history clear
Select the serial communication speed, communication I/F and
alarm history clear.
0000 Refer to
name and
function
column.
17 MOD Analog monitor output
Set the signal output for analog monitor.
0100 Refer to
name and
function
column.
Note: After setting the values of the parameters marked *, switch power off once. Switching power on again
completes the setting.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the
alarm history is cleared at next power-on.
After the alarm history is cleared, the setting
is automatically made invalid (0).
Serial communication baudrate selection
0: 9600[bps]
1: 19200[bps]
2: 38400[bps]
3: 57600
[
b
p
s
]
Analog monitor ch1 output selection
The settings and their definitions
are as in analog monitor ch2.
Analog monitor ch2 output selection
0: Motor speed (
8V/max. speed)
1: Torque (
8V/max. torque)
2: Motor speed (+8V/max. speed)
3: Torque (+8V/max. torque)
4: Current command (
8V/max.current
command)
5: Speed command (
8V/max.speed)
6: Droop pulses (
10V/128 pulses)
7: Droop pulses (
10V/2048 pulses)
8: Droop pulses (
10V/8192 pulses)
9: Droop pulses (
10V/32768 pulses)
A: Droop pulses (
10V/131072 pulses)
B: Bus voltage (+8V/400V)