Specifications
9-4
Name Display Description
Motorless operation
set 2sec
Press set
for about 2s to switch to the motorless test operation
screen.
On the motorless test operation screen, the meanings of the
keys change as described below.
mode
Changes the test operation status display screen (next
section).
The up
and down buttons are invalid.
Note: To reset the motorless test operation, switch power off,
then on.
Machine analyzer
operation
Servo Configuration
Software
Switched to the machine analyzer operation screen by
communication.
On the machine analyzer operation screen, the meanings of the
keys change as described below.
mode
Changes the test operation status display screen (next
section).
The up
and down buttons are invalid.
Note: To reset the test operation, switch power off, then on.
Software version
Low
The version of the software is displayed.
Software version
High
The system number of the software is displayed.
Option unit
software version
Low
The version of the option unit software is displayed.
Option unit
software version
High
The system number of the option unit software is displayed.
During DO signal check or test operation, the decimal point in the first digit flickers.