Specifications

8
BCN-B11127-478*
(3) How to wire the CC-Link terminal block (CN10)
(a) Strip the sheath of the cable and separate the internal wires and braided shield.
(b) Strip the sheaths of the braided shield and internal wires and twist the cores.
3-core twisted pair cable
Approx. 10mm (0.394in.)
Braided shield
(c) Match and twist the wires and braided shield of the cable connected to the preceding axis or PLC
and the corresponding wires and braided shield of the cable connected to the subsequent axis.
(d) For the last axis, work the termination resistor supplied to the CC-Link module as shown below.
Termination register
Cut
Remove sheath
(10mm (0.394in.))
Fold lead wire
(10mm (0.394in.))
Cut
Remove sheath
(e) Insert the core of the cable into the opening and tighten it with a flat-blade screwdriver so that it
will not come off. (Tightening torque: 0.5 to 0.6N
m) When inserting the wire into the opening,
make sure that the terminal screw is fully loose.
Loosen
Tighten
Opening
CC-Link terminal block
Wire
Flat blade screwdriver
Tip thickness 0.4 to 0.6mm (0.016 to 0.024in.)
Full wide 2.5 to 3.5mm (0.098 to 0.138in.)
T
o the preceding station
or PLC
To the next
station