Specifications
82
BCN-B11127-478*
11.3 CC-Link communication alarm
Any of the following indications is provided on the communication alarm display.
(Note) Communication alarm display LEDs
L.RUN SD RD L.ERR
Operation
Normal communications are made but CRC error sometimes occurs due to
noise.
Normal communications
Hardware fault
Hardware fault
Receive data resulted in CRC error and response cannot be made.
Data does not reach host station.
Hardware fault
Hardware fault
Polling response is made but refresh receive is in CRC error.
Hardware fault
Hardware fault
Hardware fault
Data addressed to host station resulted in CRC error.
Data does not reach host station or data addressed to host station cannot be
received due to noise.
Hardware fault
Baudrate setting unauthorized
Station number setting unauthorized
Baud rate or station number setting changed at any point (ERROR flickers
for about 0.4s)
Data cannot be received due to power-off, power supply section failure, open
cable or like.
WDT error occurrence (hardware fault)
Note. : On : Off : Flickering