Specifications
79
BCN-B11127-478*
Class No. Symbol Name and Function Initial Value Unit Setting Range
117 *IN2 External I/O function selection 2
Used to set the external I/O function
Setting value Initial value
Bit
1 0
Function
BIN HEX
0 Internal torque limit 0
1 Proportional control 0
2 TEMP. stop / re-start 0
3 0
0
4 0
5 0
6 0
7 0
0
8 0
9 0
A 0
B 0
0
C 0
D 0
E 0
F
Assign for CN1A / CN1B
Assign for CC-Link
Synchronous op. start 0
0
0000
118 *IN3 External I/O function selection 3
Used to set the external I/O function
Setting value Initial value
Bit
1 0
Function
BIN HEX
0 Point block # selection 1 0
1 Point block # selection 2
0
2 Point block # selection 3
0
3 Point block # selection 4
0
0
4 Point block # selection 5
0
5 0
6 0
7 0
0
8 0
9 0
A 0
B 0
0
C 0
D 0
E 0
F
Assign for CN1A / CN1B
Assign for CC-Link
0
0
0000
119
120
121
122
123
124
For manufacturing setting 0
0
0
0
0
0