Specifications

75
BCN-B11127-478*
Class No.
Symbol
Name and Function
Initial
Value
Unit Setting Range
79 *DI1 Input device selection 1
Used to select the function of CN1A-8 pin and CN1A-19 pin
Setting Input function Setting Input function
00 No function 17
01 Forced stop 18
02 Servo on 19
03 Alarm reset 1A
04 FWD stroke limit 1B
05 REV stroke limit 1C
06 FWD rotation start 1D
07 REV rotation start 1E
08 Auto. / Manu. 1F Synchronous op. start
09 20 Point block # selection 1
0A 21 Point block # selection 2
0B 22 Point block # selection 3
0C 23 Point block # selection 4
0D 34 Point block # selection 5
0E 25
0F 26
10 Internal torque limit 27
11 Proportional control 28
12 Temp. stop / Restart 29
13 2A
14 2B
15 2C
16 2D
0000
0000h
to
3F3Fh
80 *DI2 Input device selection 2
Used to select the function of CN1B-5 pin and CN1B-7 pin
0802
0000h
to
3F3Fh
81 *DI3 Input device selection 3
Used to select the function of CN1B-8 pin and CN1B-9 pin
0706
0000h
to
3F3Fh
Expansion parameters
82 *DI4 Input device selection 4
Used to select the function of CN1B-14 pin and CN1B-15 pin
011F
0000h
to
3F3Fh
Set to the function of CN1A-19 pin
Set to the function of CN1A-8 pin
Set to the function of CN1B-7 pin
Set to the function of CN1B-5 pin
Set to the function of CN1B-9 pin
Set to the function of CN1B-8 pin
Set to the function of CN1B-15 pin
Set to the function of CN1B-14 pin