Specifications

74
BCN-B11127-478*
Class No.
Symbol
Name and Function
Initial
Value
Unit Setting Range
63 LPF Low-pass filter/adaptive vibration suppression control
Used to selection the low-pass filter and adaptive vibration suppression
control.
0000 0000h
to
1217h
64 GD2B 70
65 PG2B 100
66 VG2B 100
67 VICB 100
68 *CDP 0000
69 CDS 10
70 CDT 1
71 VPI 100
72 VLI 10000
73 ERZ 10
74 ER2 10
75
STR
100
76
TRT
100
77
DBT
For manufacturing setting
100
Expansion parameters
78
*DI0
Input / Output device selection
Used to select the CN1A-19 pin to output or input device
0000 0000h
to
0001h
0
Low-pass filter selection
0: Valid (Automatic adjustment)
1: Invalid
When you choose "valid",
2 (1 GD2 setting 0.1)
VG2 setting 10
bandwidth filter is set automatically.
Adaptive vibration suppression control selection
Choosing "valid" or "held" in adaptive vibration
suppression control selection makes the machine
resonance control filter 1 (parameter No. 58) invalid.
0: Invalid
1: Valid
Machine resonance frequency is always detected
and the filter is generated in response to resonance to
suppress machine vibration.
2: Held
The characteristics of the filter generated so far are held,
and detection of machine resonance is stopped.
Adaptive vibration suppression control sensitivity selection
Used to set the sensitivity of machine resonance detection.
0: Normal
1: Large sensitivity
[H
z
]
00
0
CN1A-19 pin
0: Output device
1: Input device