Specifications

72
BCN-B11127-478*
Class No. Symbol Name and Function
Initial
Value
Unit Setting Range
54 *OP5 Function selection 5
In-position unit selection.
0000 0000h
to
1812h
55 *OP6 Optional function 6
Servo on response in alarm reset operation.
Used to select the operation to be performed when the alarm reset signal
switches on.
0000 0000h
to
1111h
56 *OP7 For manufacturing setting 0000
57 *OP8 Function selection 8
Used to select the protocol of serial communication.
0000
58 *OP9 For manufacturing setting 0000
0
In-position unit selection
0: command pulse unit
1: Encoder pulse unit
0
0
0 0 0
Operation to be performed when the
alarm reset signal switches on
0: Base circuit not switched off
1: Base circuit switched of
f
0 0
Protocol checksum selection
0: Yes (checksum added)
1: No (checksum not added)
Protocol checksum selection
0: With station numbers
1: No station numbers