Specifications
71
BCN-B11127-478*
Class No. Symbol Name and Function Initial Value Unit Setting Range
40 OVA For manufacturing setting 0
41 DSS Direct specified mode selection
0: Point block No. specified mode
1: Point instruction and block No. specified of speed and acc. / dec.
2: Instruction of position and speed
0000 0000 to 0002
42 *ZPS Zeroing position data
Used to set the current position on completion of zeroing.
0 10
S
TM
m
−32768
to
32767
43 DCT Moving distance after proximity dog
Used to set the moving distance after proximity dog in count type zeroing.
1000 10
S
TM
m
0 to 65535
44 ZTM Stopper type zeroing stopper time
In stopper type zeroing, used to set the time from when the machine part
is pressed against the stopper and the torque limit set in parameter
No.45(ZTT) is reached to when the home position is set.
100 ms 5 to 1000
45 ZTT Stopper type zeroing torque limit
Used to set the torque limit value relative to the max. torque in [%] in
stopper type zeroing.
15 % 1 to 100
46 SMX Electronic gear numerator for synchronous encoder input
8192 1
to
16384
47 SDV Electronic gear denominator for synchronous encoder input
1024 1
to
16384
48 STD Synchronous encoder Acc. / Dec. time constant
Set the Acc. / Dec. time reach to rated speed of servo motor.
This parameter will be disabled while “SYC” signal is turning on.
500 ms 0
to
20000
49 STE Synchronous encoder smoothing time constant
Set the smoothing filter for synchronous operation.
0 ms 0
to
20
50 0
51 0
52 0
53
For manufacturing setting
0