Specifications

68
BCN-B11127-478*
Class No. Symbol Name and Function Initial Value Unit Setting Range
18 *DMD Status display selection
Used to select the status display shown at power-on .
0000 0000h
to
10E6h
Basic parameters
19 *BLK Parameter block
Used to select the reference and write ranges of the parameters.
Parameter No.
Set Value Operation
#00
to
#18
#19
#20
to
#53
#54
to
#90
#91
to
#99
#100
to
#124
Reference { { × × × ×
0000
(Initial value)
Write { { × × × ×
Reference × { × × × ×
000A
Write × { × × × ×
Reference { { { × × ×
000B
Write { { × × × ×
Reference { { { × × ×
000C
Write { { { × × ×
Reference { { { { × ×
000E
Write { { { { × ×
Reference { {
{
{
{
×
000F
Write
{
{
{
{
{
×
Reference { { {
{
{
{
00AB
Write {
{
{
{
{
{
0000 0000h
to
000Eh
Status display shown at power-on
00: Current position
01: Command position
02: Command remaining distance
03: Spare
04: Cumulative feedback pulses
05: Motor speed
06: Droop pulses
07: Spare
08: Spare
09: Regenerative load ratio
0A: Effective load ratio
0B: Peak load ratio
0C: Instantaneous torque
0D: Within one-revolution position (low)
0E: Within one-revolution position (high)
0F: Spare
10: Leak inertia moment ratio
11: Bus voltage
12: Communication status
0
0